Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRISTOBAL PADRON

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CRISTOBAL PADRON in 1 WEST TOWNE MALL, MADISON, WI 53719 (NAICS 238320). OSHA activity number 341036267.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cristobal Padron — free Get an email when a new federal OSHA severe-injury report for Cristobal Padron is published. One employer, no account, unsubscribe in one click.
Establishment
CRISTOBAL PADRON
Site address
1 WEST TOWNE MALL
City
MADISON
State
WI
ZIP
53719
Mailing
499 BARNES MILL DRIVE, MARIETTA, GA 30062
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.451 E06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 30, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames were not specifically designed or constructed for use as ladder rungs:  On or about November 3, 2015, employees were accessing the scaffold working level via scaffold frames that were not intended for the use as ladder rungs.
Recent events (1)
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 3 instances 5 exposed
Issued
Dec 30, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  On or about November 3, 2015, employees working from a fabricated steel frame (walk-through) scaffolding system at a height greater than ten feet were doing so without adequate fall protection.
Recent events (1)
  • — Z (S) $2000

1926.451 G02

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(2): The employer did not have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds:  On or about November 3, 2015, prior to the dismantling of the scaffolding utilized on site, feasibility of the use of fall protection was not determined by a competent person.
Recent events (1)