PORTLAND, OR —
OSHA Inspection: VIGOR FAB LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIGOR FAB LLC in 555 N CHANNEL AVE, PORTLAND, OR 97217 (NAICS 336611). OSHA activity number 341037372.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIGOR FAB LLC
- Site address
- 555 N CHANNEL AVE
- City
- PORTLAND
- State
- OR
- ZIP
- 97217
- Mailing
- 555 N CHANNEL AVE, PORTLAND, OR 97217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 95
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 2, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $3,000 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Bay 7- (a) Employee(s) were observed using the Jet horizontal band saw, model HBS-1018W, sn# 07051550 while the saw blade's unused portion was unguarded, exposing operators to serious injuries.
Recent events (2)
- — I (S) $2700
- — Z (S) $3000
1915.56 B02
- Issued
- Dec 2, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $2,250 · Current $2,000 Reduced
General-duty citation text
29 CFR 1915.56(b)(2): Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected. (a) Building 72: On or about Oct 28, 2015 and times prior thereto a welding cable was cut to the conductor 6 feet from the work lead. This exposed employees to potential electrical shock hazard if employee contacted conductor during welding operations. (b) New Tugboat build: On or about Oct 28, 2015 and times prior thereto a welding cable was cut to the conductor 8 feet from the work lead. This exposed employees to potential electrical shock hazard if employee contacted conductor during welding operations. (c) New barge build: On or about Oct 28, 2015 and times prior thereto a welding cable was cut to the conductor. This exposed employees to potential electrical shock hazard if employee contacted conductor during welding operations.
Recent events (2)
- — I (S) $2000
- — Z (S) $2250
1915.504 B03
- Issued
- Dec 2, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $2,250 · Current $2,000 Reduced
General-duty citation text
29 CFR 1915.504(b)(3): The employer did not post a fire watch when there was combustible material less than 35 feet in either the horizontal or vertical direction that could not be removed, was not protected with flame-proof covers or shielded with metal fire-resistant guards or curtains. Harley 83 barge tank 4: On or about October 28, 2015 and times prior thereto, two employees were working in a tank with combustibles in the tank and there was no fire-watch or fire extinguisher in the tank. This exposed the two employees to burns and smoke inhalation hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $2250
1910.305 J02 V
- Issued
- Dec 2, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed. Weatherdeck of new barge build: On or about October 28, 2015 and times prior thereto, weather covers were missing off of the electrical junction boxes. This exposed employees to potential electrical hazards if water penetrated into the electrical circuitry.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Vigor FAB LLC
View Vigor FAB LLC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341037372.