Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PAUL'S RECYCLING INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of PAUL'S RECYCLING INC. in 2199 GARWOOD STREET, SIKESTON, MO 63801 (NAICS 423930). OSHA activity number 341039436.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paul'S Recycling INC. — free Get an email when a new federal OSHA severe-injury report for Paul'S Recycling INC. is published. One employer, no account, unsubscribe in one click.
Site address
2199 GARWOOD STREET
City
SIKESTON
State
MO
ZIP
63801
Mailing
P.O. BOX 1986, SIKESTON, MO 63801
Inspection type
Follow-up (F)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
22
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 8 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:  Specific procedures were not developed in writing for the following pieces of equipment:  a/  Allon Material Handler, m/n 1A95B42140482161, s/n 14068.  b/  Case 586 Material Handler, m/n JJG025184, s/n m/n 580E.  c/  Case 621 Material Handler, m/n 621B, s/n JEE0042853.  d/  Hyundai Material Handler, m/n ROBEX-200LC, s/n E3360M.  e/  Doosan 225 Material Handler, m/n SOLAR 225LC-V, s/n 50002086.  f/  Doosan 300 Material Handler, m/n DX300LC, s/n 70006181.  g/  Toyota Fork Truck, m/n 7FDU30, s/n 61675.  h/  Komatsu 300 Material Handler, m/n PC300LC-6LC, s/n A80528.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, Items A-D of this section:  a/  Inside of the Metal Building, the specific, documented procedure for the Harmony Enterprises Vertical Baler, m/n T60XDRC, s/n T60XDRC-0268, did not include gravity and hydraulic energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 9 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  Suitable lockout/tagout devices were not provided or utilized for the effective isolation of gravity, hydraulics, and residual electrical energy belonging to the following pieces of equipment:  a/  Harmony Enterprises Vertical Baler, m/n T60XDRC, s/n T60XDRC-0268.  b/  Allon Material Handler, m/n 1A95B42140482161, s/n 14068.  c/  Case 586 Material Handler, m/n JJG025184, s/n m/n 580E.  d/  Case 621 Material Handler, m/n 621B, s/n JEE0042853.  e/  Hyundai Material Handler, m/n ROBEX-200LC, s/n E3360M.  f/  Doosan 225 Material Handler, m/n SOLAR 225LC-V, s/n 50002086.  g/  Doosan 300 Material Handler, m/n DX300LC, s/n 70006181.  h/  Toyota Fork Truck, m/n 7FDU30, s/n 61675.  i/  Komatsu 300 Material Handler, m/n PC300LC-6LC, s/n A80528.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.147(c)(7)(i)(A):  The employer did not provide adequate training to ensure that employees required the knowledge and skills required for the safe application, usage, and removal of energy control devices:  a/  Authorized employees were unfamiliar with the requirement to apply suitable lockout/tagout devices for the effective isolation of gravity, hydraulics, and residual electrical energy sources.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.147 D04 I

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  Suitable lockout/tagout devices were not affixed or utilized for the effective isolation of gravity, hydraulics, and residual electrical energy belonging to the following pieces of equipment:  a/  Harmony Enterprises Vertical Baler, m/n T60XDRC, s/n T60XDRC-0268.  b/  Allon Material Handler, m/n 1A95B42140482161, s/n 14068.  c/  Case 586 Material Handler, m/n JJG025184, s/n m/n 580E.  d/  Case 621 Material Handler, m/n 621B, s/n JEE0042853.  e/  Hyundai Material Handler, m/n ROBEX-200LC, s/n E3360M.  f/  Doosan 225 Material Handler, m/n SOLAR 225LC-V, s/n 50002086.  g/  Doosan 300 Material Handler, m/n DX300LC, s/n 70006181.  h/  Toyota Fork Truck, m/n 7FDU30, s/n 61675.  i/  Komatsu 300 Material Handler, m/n PC300LC-6LC, s/n A80528.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.178 P01

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.178(p)(1):  Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s):  a/  Inside of the Metal Building, the rear, solid rubber tires belonging to the Toyota Fork Truck, m/n 7FDU30, s/n 6167S, were missing large pieces of rubber.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.215 A04

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.215(a)(4):  Grinding machinery was not used with work rests(s) to support off-hand grinding work:  a/  Inside of the Metal Building, two, Skil 3380 Bench Mounted Grinders were not equipped with a work rest.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.215 B09

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  a/  Inside of the Metal Building, the peripheral guard belonging to two, Skil 3380 Bench Mounted Grinders was approximately .5 inches away from the abrasive wheels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.303(b)(7)(iv):  There were damaged parts that would adversely affect the safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  a/  Inside of the Metal Building, the outer cover belonging to a 220 volt receptacle that supplied electrical power to a Pro-Wash Power Washer, m/n unknown, s/n unknown, was broken.  The inner wiring was exposed to wet conditions.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.305 G01 IV D

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:  a/  Inside of the Metal Building, the red, flexible cord that supplied 120 volt electrical power to a Skil 3380 Bench Mounted Grinder was attached to the plywood wall.
Recent events (2)
  • — I (S) $220
  • — Z (S) $2200

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 18, 2015
Abate by
Jan 7, 2016
Penalty
Initial $2,200 · Current $220 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a/  Inside of the Yard, the plug attached to a flexible cord that provided 220 volt electrical power to a Pro Wash Power Wash, unknown m/n, unknown s/n, was not equipped with strain relief.  The inner wiring was exposed to wet conditions.