Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHEASTERN COMMERCIAL ROOFING & RESTORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHEASTERN COMMERCIAL ROOFING & RESTORATION in 171 GENESEE STREET, UTICA, NY 13501 (NAICS 238160). OSHA activity number 341039634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northeastern Commercial Roofing & Restoration — free Get an email when a new federal OSHA severe-injury report for Northeastern Commercial Roofing & Restoration is published. One employer, no account, unsubscribe in one click.
Site address
171 GENESEE STREET
City
UTICA
State
NY
ZIP
13501
Mailing
1140 WEBSTER AVENUE, UTICA, NY 13501
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.59

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2015
Abate by
Jan 21, 2016
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.59 referencing 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a)  At the jobsite, accessing the roof, on or about 10/22/15:  Employees used liquid adhesives and aerosol adhesives where SDS's were not available at the jobsite, and where a written HAZCOM program was not established or implemented.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $2200

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2015
Abate by
Dec 23, 2015
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  a)  At the jobsite, on the 5th floor, on or about 10/22/15:  Employees were using power tools and an electrical source where that source was not GFCI protected.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $2200

1926.150 C01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2015
Abate by
Dec 23, 2015
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:  a)  At the jobsite, on the 5th floor, on or about 10/22/15:  Employees were storing and disposing flammable materials used for roofing work on the 5th floor where no fire extinguisher was available.  Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $2200

1926.501 B04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 17, 2015
Penalty
Initial $2,640 · Current $2,640
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems:  a)  At the jobsite, on the 5th floor, on or about 10/22/15:  Employees transited this area multiple times per day to access and egress the roof area, while an unprotected hole was in close proximity to the walking path from the top of the stairs to the ladder accessing the roof.
Recent events (1)
  • — Z (S) $2640

1926.1053 A01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2015
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.1053(a)(1)(ii): Non-self-supporting portable ladder(s) were not capable of supporting without failure, at least four times the maximum intended load:  a)  At the jobsite, accessing the roof, on or about 10/22/15:  Employees used a job built ladder to access the roof, 11 feet from the 5th floor, and where that wooden ladder did not have cleats installed between any of the wrungs.
Recent events (1)
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a)  At the jobsite, accessing the roof, on or about 10/22/15:  Employees used a job built ladder to access the roof, 11 feet from the 5th floor, and where that wooden ladder did reach at least 3 feet above the landing being accessed.
Recent events (1)
  • — Z (S) $0

View Northeastern Commercial Roofing & Restoration's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341039634.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.