Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ENERGY EXCHANGER COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENERGY EXCHANGER COMPANY in 1844 N. GARNETT RD., TULSA, OK 74116 (NAICS 332410). OSHA activity number 341040913.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energy Exchanger Company — free Get an email when a new federal OSHA severe-injury report for Energy Exchanger Company is published. One employer, no account, unsubscribe in one click.
Site address
1844 N. GARNETT RD.
City
TULSA
State
OK
ZIP
74116
Mailing
1844 N. GARNETT RD., TULSA, OK 74116
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2016
Abate by
Jan 21, 2016
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers, vehicles, and equipment without electrically interconnecting the nozzle and the container, vehicles, or equipment:    On or about November 4, 2015, and at times prior thereto, in the flammable storage area gasoline having flashpoint of -45 degrees F was dispensed into another container and/or equipment without being effectively grounded and bonded to electrically interconnect the containers and/or equipment to prevent static discharge during dispensing operation exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.179 B05

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 12, 2016
Abate by
Feb 4, 2016
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.179(b)(5): Crane(s) with more than one hoisting unit did not have the rated load marked on each hoisting unit or load block:     On or about September 04, 2015, and at times prior thereto, in the machine shop area overhead a crane's load block was observed not having the rated load clearly marked.  Employees were exposed to struck by hazards.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.179 G01 V

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 12, 2016
Abate by
Feb 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:    On or about September 4, 2015, and at times prior thereto, in the machine shop areas an overhead crane pendant control box was observed having some control buttons not clearly marked for identification and function.  The employees were exposed to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02

Serious Gravity 5 1 instance 50 exposed
Issued
Jan 12, 2016
Abate by
Feb 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2): The items listed in subparagraphs (j)(2)(i)-(vii) were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard     On or about September 4, 2015, and at times prior thereto, at the facility overhead cranes being used to lift heavy objects, the items listed in subparagraph (j)(2)(I)-(vii) were not inspected for defects monthly.  Employees were exposed to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Energy Exchanger Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341040913.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.