Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELQ INDUSTRIES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ELQ INDUSTRIES INC. in 57 NORTH CENTRAL AVENUE, HARTSDALE, NY 10530 (NAICS 237110). OSHA activity number 341042042.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ELQ Industries INC. — free Get an email when a new federal OSHA severe-injury report for ELQ Industries INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ELQ INDUSTRIES INC.
Site address
57 NORTH CENTRAL AVENUE
City
HARTSDALE
State
NY
ZIP
10530
Mailing
567 5TH AVENUE, NEW ROCHELLE, NY 10801
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.652 C04 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Apr 21, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1926.652(c)(4)(i): Support systems, shield systems, and other protective systems not utilizing Option 1, Option 2 or Option 3, were not approved by a registered professional engineer:  On or about 10/30/15  Location: IFO, 57 North Central Avenue, Hartsdale, NY 10530  a) Employees repairing a water main in a 10 foot wide, 17 foot long, 10 foot deep excavation were not protected by a protective system approved by a registered engineer. The excavation was in material, K-Crete Lean Mix, that does not fall into a OSHA soil or stable rock category allowing for the use of Options 1, 2 or 3.  b) Employees repairing a water main in a 10 foot wide, 17 foot long, 10 foot deep excavation were not protected by a protective system approved by a registered engineer. The timber shoring provided did not meet the requirement utilizing Option 1, Appendix A, Soil type A (Least Protective) in that 3x10 pieces were used as cross braces instead of 6x6 pieces and the ends of the excavation where the pipe entered/exited was not protected. The use of a system lower in protection strength than the lowest rated OSHA system was not approved by a registered engineer.
Recent events (3)
  • — C (S) $7000
  • — F (S) $0
  • — Z (S) $7000

View ELQ Industries INC.'s full OSHA safety record →