MONROE, LA —
OSHA Inspection: QUALITY SHEET METAL INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUALITY SHEET METAL INC in 2428 STERLINGTON ROAD, MONROE, LA 71203 (NAICS 332999). OSHA activity number 341042810.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY SHEET METAL INC
- Site address
- 2428 STERLINGTON ROAD
- City
- MONROE
- State
- LA
- ZIP
- 71203
- Mailing
- 2428 STERLINGTON ROAD, MONROE, LA 71203
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 II
- Issued
- Jan 21, 2016
- Abate by
- Feb 17, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. On or about 11/5/15, throughout the fabrication shop and yard; the employer allowed employees to operate the Toyota Propane fork trucks (Model 7FGU30 Serial #64436) without documentation that the operators had successfully completed the training required by this standard.
Recent events (1)
- — Z (S) $1200
1910.178 P01
- Issued
- Jan 21, 2016
- Abate by
- Feb 17, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) On or about 11/5/15, throughout the fabrication shop and yard; the employer allowed employees to operate the Toyota Propane fork truck (Model 7FGU30 Serial #64436) without a working seatbelt.
Recent events (1)
- — Z (S) $1200
1910.212 A01
- Issued
- Jan 21, 2016
- Abate by
- Feb 17, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and flying chips and point of operation a) On or about 11/5/2015; in the Northwest corner of the shop; the employer allowed employees to operate the Johansson Drill Press (Serial #11127) without a guard around the chuck and bit; b) On or about 11/5/2015; in the middle South side of shop; the employer allowed employees to operate the Adira Hydraulic Press (Model QHD-15040 Serial 48078997) without a guard to prevent entry by reaching through, over, under and around the point of operation.
Recent events (1)
- — Z (S) $1600
1910.147 C01
- Issued
- Jan 21, 2016
- Abate by
- Feb 17, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 11/5/2015; middle south side of the shop, the employer allowed employees not to lockout the Adira Shear (Model #GHS 0630; Serial #32838896D) when the die is changed every two years. A lockout program was not developed nor implemented.
Recent events (1)
- — Z (O) $0
1910.157 E04
- Issued
- Jan 21, 2016
- Abate by
- Feb 17, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(4): Stored pressure dry chemical portable fire extinguishers that require a 12 year hydrostatic test were not emptied and subjected to applicable maintenance procedures every 6 years: On or about 11/5/15 at the east end of the fabrication shop at the sliding door; the employer allowed #5 ABC fire extinguishers to be used by employees and the extinguishers had not been serviced since 2005
Recent events (1)
- — Z (O) $0
More inspections at Quality Sheet Metal INC
View Quality Sheet Metal INC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341042810.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.