PORTLAND, OR —
OSHA Inspection: VIGOR MARINE LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of VIGOR MARINE LLC in 5555 N CHANNEL AVE, PORTLAND, OR 97217 (NAICS 336611). OSHA activity number 341044766.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIGOR MARINE LLC
- Site address
- 5555 N CHANNEL AVE
- City
- PORTLAND
- State
- OR
- ZIP
- 97217
- Mailing
- 5555 N CHANNEL AVE, PORTLAND, OR 97217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 200
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.303 B01 VI
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $3,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(vi): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. Arcing effects was not taken into consideration in determining the safety of the equipment. (a) Located in the machine house of crane #10: On or about and at times prior to switches, fuses and other exposed live electric parts were not adequately shielded to prevent serious injury to employees in the event of an arc flash incident.
Recent events (2)
- — I (S) $2000
- — Z (S) $3000
1910.303 B07 IV
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating. (a) Located in the basin of dry dock #3: On or about and at times prior October 27, 2015 the inspection revealed that on a portable welding system outlet #8 was missing the weather cover. (b) Located at the US Fab building way next to the barge under construction on the port side, midway: On or about and at times prior October 27, 2015 the inspection revealed that on the load center #3 electrical box two of the receptacle outlet boxes were missing weather cover. (c) Located on the port side wing wall of dry dock #3 at frame 95: On or about and at times prior to October 27, 2015 the inspection revealed a portable panel with damaged outlet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 B03 II A
- Issued
- Mar 10, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel. (a) Located in the basin of dry dock #3: On or about and at times prior to October 27, 2015 employees were potentially exposed to serious injury from the use of tools with a flexible pendant outlet that was connected to portable welding system and did not have a ground fault circuit interrupter.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J02 IV
- Issued
- Mar 10, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: (a) Located throughout Vigor Shipyard: On or about and at times prior to October 26, 2015 the inspection revealed that shop made pendant temporary outlets were used in wet locations such as drydocks and the weather decks of vessels and were not designed for a wet location.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.152 A
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $3,750 · Current $2,200 Reduced
General-duty citation text
29 CFR 1915.152(a): The employer did not provide or ensure each affected employee with the appropriate personal protective equipment (PPE) for the eyes, face, head, extremities, torso, and respiratory system, including protective clothing, protective barriers, personal fall protection equipment, and life saving equipment, meeting the applicable provisions of Subpart I, wherever employees were exposed to work activity hazards that required the use of PPE. (a) Located at berth 312 at the waterside edge of the pier: On October 26, 2015 an employee were potentially exposed to serious injury or death because the employer did not ensure that the employee wore his life jacket when exposed to a fall into the water of about 30 feet. (b) Located at berth 313 at the waterside edge of the pier: On October 26, 2015 four rigging employees were potentially exposed to serious injury or death because the employer did not ensure that the employees wore their life jackets when exposed to a fall into the water of about 30 feet.
Recent events (2)
- — I (S) $2200
- — Z (S) $3750
1910.303 E01 II
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Markings were not provided on electrical equipment for voltage, current, wattage and other ratings as necessary. (a) Located inside the machine house of the crane #10: On or about and at times prior to October 27, 2015 the inspection revealed that electrical equipment including switches and fuses was not labeled to indicated voltage, current, or wattage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 E01
- Issued
- Mar 10, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: (a) Located at dry dock 3, port side wing wall, frame 95: On or about and at times prior to October 27, 2015 the inspection revealed a portable circuit breaker panel did not have a door to provide protection from the weather.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.306 B04
- Issued
- Mar 10, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.306(b)(4): Where controls were enclosed in cabinets, the doors did not open at least 90 degrees nor were they removable. (a) Located in crane adjacent to dry dock 3: On or about and at times prior to October 27, 2015 the inspection revealed that the particle board shielding switches and fuses with exposed live electrical parts was not removable and no longer slid open on rollers as the design was intended.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1025 D06 III
- Issued
- Mar 10, 2016
- Abate by
- Apr 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(d)(6)(iii) is applicable to shipyard employment by 29 CFR 1915.1025 that incorporates the General Industry requirement: Where the initial monitoring revealed that employee exposure to lead was above the permissible exposure limit, ; monitoring was not repeated at least quarterly and continued at the required frequency until at least two consecutive measurements taken at least 7 days apart were below the PEL and at or above the action level: (a) Located at Vigor Shipyard in Portland Oregon: On October 28, 2015 the inspection revealed that the employer did not conduct industrial hygiene monitoring to determine employee exposure levels to lead at least quarterly after sampling conducted by PBS Environmental on October 24, 2014 revealed an employee exposure to lead greater than OSHA's Permissible Exposure Limit (PEL).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.56 E
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.56(e): Arc welding and cutting operations were not shielded by noncombustible or flameproof screens to protect employees in the vicinity from the direct rays of the arc. (a) Located on the main deck of the vessel USNS Henry J Kaiser: On or about and at times prior to October 26, 2015 the inspection revealed that employees were conducting welding operations in an open area and were not protecting other employees in the vicinity with welding screens.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.87 E
- Issued
- Mar 10, 2016
- Abate by
- Apr 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.87(e): The employer did not ensure that quick-drenching and flushing of the eyes and body were located for immediate emergency use and within close proximity to the operations where such substances were being used. (a) Located in the main basin of drydock #3: On or about and at times prior to October 27, 2015 the inspection revealed that corrosives were in use in an area that was not in close proximity to the nearest eyewash.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Vigor Marine LLC
View Vigor Marine LLC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341044766.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.