OSHA Inspection: ACTION BAG COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACTION BAG COMPANY in 751 N ROHLWING RD., ITASCA, IL 60143 (NAICS 424130). OSHA activity number 341044956.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Action BAG Company — free Get an email when a new federal OSHA severe-injury report for Action BAG Company is published. One employer, no account, unsubscribe in one click.
Establishment
ACTION BAG COMPANY
Site address
751 N ROHLWING RD.
City
ITASCA
State
IL
ZIP
60143
Mailing
1001 ENTRY DRIVE, BENSENVILLE, IL 60106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424130
Employees
7
Ownership type
A

2 citations on file for this inspection.

1910.303 B02

Other-than-serious 1 instance 7 exposed
Issued
Nov 25, 2015
Penalty
Initial $1,607 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     Warehouse, employee break area.  A relocatable power tap (temporary power strip), which was not designed for use in an industrial environment, was used to supply power to a flexible cord for a microwave, exposing employees to overloading and overheating of electrical components that could contribute to a fire.    There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1607

1910.305 G01 III

Other-than-serious 1 instance 7 exposed
Issued
Nov 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iii): Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not equipped with an attachment plug and energized from an approved receptacle outlet:    Warehouse, employee break area.  A flexible cord for a microwave oven was plugged into a relocatable power tap (power strip) and not energized directly from an outlet, exposing employees to overloading and overheating of electrical components that could contribute to a fire.    There is no abatement certification or documentation required for this item.