Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: WISCONSIN LIGHTING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of WISCONSIN LIGHTING, INC. in 155 W 3RD ST, NEW RICHMOND, WI 54017 (NAICS 322233). OSHA activity number 341051423.

Watch Wisconsin Lighting, INC. — free Get an email when a new federal OSHA severe-injury report for Wisconsin Lighting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
155 W 3RD ST
City
NEW RICHMOND
State
WI
ZIP
54017
Mailing
155 W 3RD ST, NEW RICHMOND, WI 54017
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322233
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $2100.00
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   (a) Throughout the facility; A written respiratory protection program was not developed and implemented for employees required to wear half-mask and filtering facepiece respirators when performing spray finishing operations.
Recent events (1)
  • — Z (S) $2100

1910.134 D01 III

Serious Gravity 1 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a) Throughout the facility; The employer did not identify and evaluate employee exposure to respiratory hazards including, but not limited to, xylene, butanone, ethylbenzene, and various other volatile organic compounds.
Recent events (1)
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees' ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:  (a) Throughout the facility; Medical evaluations were not provided prior to use to determine employees ability to use half-mask and filtering facepiece respirators while employees were working with chemicals, including but not limited to, xylene, butanone, ethylbenzene, and various other volatile organic compounds.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  (a) Throughout the facility; Employees required to wear half-mask and filtering facepiece respirators were not fit tested, prior to initial use of respirators; respirators were utilized for protection against chemicals, including but not limited to, xylene, butanone, ethylbenzene, and various other volatile organic compounds.
Recent events (1)
  • — Z (S) $0

1910.134 K01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii):  (a) Throughout the facility; Employees required to wear half-mask and filtering facepiece respirators were not trained on the necessary elements of the respirator standard; respirators were utilized for protection against chemicals, including but not limited to, xylene, butanone, ethylbenzene, and various other volatile organic compounds.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Throughout the facility; A written hazard communication program was not developed, implemented, and maintained.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341051423.