OSHA Inspection: IVY BIOMEDICAL SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IVY BIOMEDICAL SYSTEMS, INC. in 11 BUSINESS PARK DRIVE, BRANFORD, CT 06405 (NAICS 334510). OSHA activity number 341057867.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IVY Biomedical Systems, INC. — free Get an email when a new federal OSHA severe-injury report for IVY Biomedical Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 BUSINESS PARK DRIVE
City
BRANFORD
State
CT
ZIP
06405
Mailing
11 BUSINESS PARK DRIVE, BRANFORD, CT 06405
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334510
Employees
53
Ownership type
A

5 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).   WORKSHOP:   The employer had not assessed the workplace to determine the necessitate and appropriate types of personal protective equipment (PPE) for the employees.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.132 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE.   WORKSHOP:  The employer had not trained all the employees on the Workplace hazard assessment for personal protective equipment (PPE).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV E

Serious Gravity 5 3 instances 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.305(g)(1)(iv)(E): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where concealed behind building walls, ceilings, floors, or other structures:  WORKSHOP:  The black flexible cord of the work benches was wrapped around and concealed behind the the carbon dioxide cylinder/tankt.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.  WORKSHOP:  The employer had not established and implemented a written hazard communication program where employees were required to work with chemicals, such as (but not limited to) isopropyl alcohol and solder.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.1200 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2015
Abate by
Feb 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  WORKSHOP:  The employer did not maintain a safety data sheet for the carbon monoxide contained inside the cylinder/tank.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View IVY Biomedical Systems, INC.'s full OSHA safety record →