FLORENCE, AL —
OSHA Inspection: JOSH RICKMAN
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JOSH RICKMAN in 9000 COUNTY ROAD 47, FLORENCE, AL 35634 (NAICS 337110). OSHA activity number 341088425.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOSH RICKMAN
- Site address
- 9000 COUNTY ROAD 47
- City
- FLORENCE
- State
- AL
- ZIP
- 35634
- Mailing
- 9000 COUNTY ROAD 47, FLORENCE, AL 35634
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 4
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.107 B01
- Issued
- Apr 25, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.107(b)(1): The spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry: a) On or about February 23, 2015 - Cabinet shop, employees were exposed to fire hazards as a result of spray finishing of flammable paint products used in a spray booth that was constructed of wood.
Recent events (1)
- — Z (S) $1600
1910.107 D05
- Issued
- Apr 25, 2016
- Abate by
- Jun 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(5): Electric motor(s) driving exhaust fan(s) for spray booth(s) were located inside the booth(s): (a) On or about November 30, 2015 - Cabinet shop, employees were exposed to fire hazards due to an oscillating pedestal fan with an electric motor being used for venting the spray booth.
Recent events (1)
- — Z (S) $0
1910.107 G05
- Issued
- Apr 25, 2016
- Abate by
- Jun 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(5): The employer shall not use a cleaning solvent with a lower flashpoint than the solvents used for spray painting operations: (a) On or about November 30, 2015 - Cabinet shop, lacquer thinner with a flash point of 1 degree F was used to clean spray nozzles and equipment.
Recent events (1)
- — Z (S) $0
1910.107 C06
- Issued
- Apr 25, 2016
- Abate by
- May 28, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: (a) On or about November 30, 2015 - Cabinet shop, fluorescent light fixtures without covers were used to illuminate the paint room.
Recent events (1)
- — Z (S) $1200
1910.134 C01
- Issued
- Apr 25, 2016
- Abate by
- May 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) On or about November 30, 2015 - Cabinet shop, a written respiratory protection program had not been developed and implemented for employees required by the employer to wear a 3M half-facepiece respirator when spray painting cabinets.
Recent events (1)
- — Z (O) $0
1910.134 E01
- Issued
- Apr 25, 2016
- Abate by
- May 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about November 30, 2015 - Cabinet shop, medical evaluations were not provided to employees required to wear a 3M half-face respirator when spray finishing cabinets.
Recent events (1)
- — Z (O) $0
1910.134 G01 I A
- Issued
- Apr 25, 2016
- Abate by
- May 8, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) On or about November 30, 2015 - Cabinet shop, the employer allowed employees with facial hair to wear tight fitting respirators.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Apr 25, 2016
- Abate by
- Jun 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about February 23, 2015 - Cabinet shop, a written hazard communication program had not been developed and implemented for employees working in and around chemicals, including but not limited to, paint, sealer, and lacquer thinner.
Recent events (1)
- — Z (O) $0
1910.1200 H01
- Issued
- Apr 25, 2016
- Abate by
- May 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On or about February 23, 2015 - Cabinet shop, employees were not provided effective information and training regarding the hazards associated with paint products, including but not limited to, paint, sealer, and lacquer thinner.
Recent events (1)
- — Z (O) $0
More inspections at Josh Rickman
View Josh Rickman's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341088425.