OSHA Inspection: BORETS U.S., INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BORETS U.S., INC. in 2222 COMMERCE DRIVE, MIDLAND, TX 79703 (NAICS 333911). OSHA activity number 341108884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Borets U.S., INC. — free Get an email when a new federal OSHA severe-injury report for Borets U.S., INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BORETS U.S., INC.
Site address
2222 COMMERCE DRIVE
City
MIDLAND
State
TX
ZIP
79703
Mailing
1600 N. GARNETT RD, TULSA, OK 74116
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333911
Employees
69
Ownership type
A

3 citations on file for this inspection.

1910.253 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 12, 2016
Abate by
Mar 4, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:  The employer did not ensure oxygen cylinders, in the manufacturing area, were stored away from acetylene cylinders while not in use and exposed employees to fire hazards.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.303 G01 II

Serious Gravity 5 2 instances 7 exposed
Issued
Feb 12, 2016
Abate by
Mar 4, 2016
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing:  Employees of Borets U.S., Inc., were exposed to burn and struck-by hazards, in the panelboard room of the testing area, while access to electrical panels was blocked with materials.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.305 D02

Serious Gravity 5 3 instances 8 exposed
Issued
Feb 12, 2016
Abate by
Mar 4, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.  The employer did not ensure that electrical panelboards, in the testing area panelboard room, was mounted with the door closed and exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000