CALVERT CITY, KY —
OSHA Inspection: JAMES BUILT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAMES BUILT in 390 RIVERSIDE LANE, CALVERT CITY, KY 42029 (NAICS 336611). OSHA activity number 341109718.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JAMES BUILT
- Site address
- 390 RIVERSIDE LANE
- City
- CALVERT CITY
- State
- KY
- ZIP
- 42029
- Mailing
- PO BOX 2305 4500 CLARKS RIVER RD, PADUCAH, KY 42002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 50
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B04 III
- Issued
- Jan 29, 2016
- Abate by
- Feb 25, 2016
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least (a) Building 2- On or about 12/9/15, employees were exposed to fire and explosion hazards when oxygen and acetylene cylinders were not stored properly. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.305 G02 III
- Issued
- Jan 29, 2016
- Abate by
- Feb 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Building 3 - On or about 12/9/15, strain relief was not provided on an extension cord. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.55 A09
- Issued
- Jan 29, 2016
- Abate by
- Feb 10, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.55(a)(9): Acetylene cylinders were not secured in an upright position. a) Building 2 - On or about 12/9/15, employees were exposed to struck-by hazards when an acetylene cylinder was not secured to prevent from tipping over. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at James Built
View James Built's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in KY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341109718.