Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INNOVATIVE CONSTRUCTION & ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INNOVATIVE CONSTRUCTION & ROOFING LLC in 401 MAR-LE DRIVE, WENTZVILLE, MO 63385 (NAICS 238160). OSHA activity number 341110377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Innovative Construction & Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Innovative Construction & Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
401 MAR-LE DRIVE
City
WENTZVILLE
State
MO
ZIP
63385
Mailing
10850 BAUR BLVD., SAINT LOUIS, MO 63132
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
18
Ownership type
A

1 citation on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 9 exposed
Issued
Dec 17, 2015
Abate by
Jan 4, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.20(b)(2):  Such programs did not provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  On 12/09/2015, the subcontractor for Innovative Construction & Roofing LLC, was installing a roofing membrane on the roof of a commercial building located at 401 Mar-Le Drive, Wentzville MO. Two foremen from Innovative Construction & Roofing LLC were on the roof at the site while the employees were working.  The foremen did not conduct an adequate inspection of the job site, materials, and equipment.  During the inspection, the subcontractor's employees were exposed to the following hazard:  a)The crew leader and nine employees were repairing the roof, which was approximately ten feet above the ground, without the proper use of guardrail systems, safety net systems, or personal fall arrest systems or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.
Recent events (1)
  • — Z (S) $2800

View Innovative Construction & Roofing LLC's full OSHA safety record →