MANHEIM, PA —
OSHA Inspection: DENT WIZARD INTERNATIONAL CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DENT WIZARD INTERNATIONAL CORPORATION in 1190 LANCASTER RD, MANHEIM, PA 17545 (NAICS 811121). OSHA activity number 341120202.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DENT WIZARD INTERNATIONAL CORPORATION
- Site address
- 1190 LANCASTER RD
- City
- MANHEIM
- State
- PA
- ZIP
- 17545
- Mailing
- 4710 EARTHCITY EXPRESSWAY ATTN: SUE SCOTT, MANAGER HEALTH AND SAFETY, BRIDGETON, MO 63044
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 47
- Ownership type
- A
Citations
18 citations on file for this inspection.
1910.107 B01
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $6,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(b)(1): The spray booth was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Trailer #1 used in spray painting wheel rims was constructed primarily of plywood flooring, sidewalls and doors, on or about December 14, 2015. b) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Trailer #2 used in spray painting wheel rims was constructed primarily of plywood flooring, sidewalls, and doors, on or about December 14, 2015. c) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Trailer #3 used in spray painting wheel rims was constructed primarily of aluminum diamond plated flooring and walls, on or about December 14, 2015. d) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Trailer #4 used in spray painting wheel rims was constructed primarily of aluminum diamond plated flooring and walls, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $6000
- — Z (S) $6000
1910.107 B03
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, if combustible, were not covered with non-combustible material of such character as to facilitate the safe cleaning and removal of residues: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The floor of trailer #1 used in spray painting wheel rims was constructed of plywood flooring, on or about December 14, 2015. b) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The floor of trailer #2 used in spray painting wheel rims was constructed of plywood flooring, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 B05 I
- Issued
- Jun 1, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $0 · Current $3,600
13772460H130
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or ensure that the required air velocity was maintained; and filter rolls were not inspected to insure proper replacement of filter media: (a) Dent Wizard International Corporation; Wheel Repair Area - The four (4) trailers that were used to spray paint the wheels were not equipped with gauges to ensure adequate air velocity was maintained, on or about December 14, 2015. (b) Dent Wizard International Corporation; Wheel Repair Area - The filters were not inspected to insure proper filter media replacement and the filters needed to be changed in several sections of the trailers, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $3600
- — C (S) $0
- — Z (S) $0
1910.107 B05 IV
- Issued
- Jun 1, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth(s) on the downstream and upstream sides of the filters were not protected with approved automatic sprinklers: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Each of the four trailers used in spray painting wheel rims was not provided with automatic sprinklers on either the upstream or the downstream side of the filter media, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s): a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In trailer #2 a flammables cabinet, cardboard boxes, and containers where stored within the paint booth, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 B10
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(10): Panels used for illumination of spray booth(s) did not effectively isolate the spraying area from the area in which the lighting unit(s) were located, panels were not arranged such that normal accumulations of residue on the exposed surface of the panel could not be raised to a dangerous temperature by radiation or conduction from the source of illumination: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Fluorescent lights in trailer #1 used for spray painting operations were not designed/approved for class 1 environments, combustible residue was observed on the fixtures subjecting the combustible residue to high temperatures, on or about December 14, 2015. b) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Fluorescent lights in trailer #2 used for spray painting operations were not designed/approved for class 1 environments, combustible residue was observed on the fixtures subjecting the combustible residue to high temperatures, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 C03
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $6,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.107(c)(3): Hot surfaces were located in spraying area(s) where deposits of combustible residues could readily accumulate: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In trailer #1 a 60,000 BTU Dyna-glow portable propane heater placed on the floor was used to bake the wheel rims, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $3600
- — C (S) $6000
- — Z (S) $6000
1910.107 C04
- Issued
- Jun 1, 2016
- Abate by
- Sep 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(4): Electrical wiring and equipment did not conform to the provisions of this paragraph and were not otherwise in accordance with subpart S of this part (Reference: 29 CFR 1910.307, Hazardous Locations): a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer does not ensure that only approved electrical equipment is located in areas subject to ignitable residues and explosive vapors. On or about December 14, 2015, in each of the four trailers used in spray paint operations, electrical wiring equipment not limited to switches, circuit breakers, receptacles, heat lamps, and junction boxes were not of an intrinsically safe design and safe for the hazardous location. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 C05
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): instanced (a) & (b) deleted a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer does not ensure that only approved electrical equipment is located in areas subject to ignitable residues and explosive vapors. On or about December 14, 2015, in trailer #1 residue was observed on two wall mounted junction boxes with small screw openings. b) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer does not ensure that only approved electrical equipment is located in areas subject to ignitable residues and explosive vapors. On or about December 14, 2015, in trailer #2 residue was observed on a 120v circuit breaker with a missing knockout. c) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer does not ensure that only approved electrical equipment is located in areas subject to ignitable residues and explosive vapors. On or about December 14, 2015, in trailer #3 residue was observed on a 120v heat lamp and switches. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 E02
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $6,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer did not ensure that the quantity of flammable liquids in the vicinity of spraying operations was kept at the minimum and not exceeding a day's use. In trailer #2 there were flammable liquids in 1-gallon containers, including but not limited to: RM UR40 low temp reducer; RM DC21NB clear coat; DH57 normal hardner; DP26 primer; and RM DH42 primer, on or about December 14, 2015. These liquids represented more than a day's supply. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $3600
- — C (S) $6000
- — Z (S) $6000
1910.107 G02
- Issued
- Jun 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $6,000 · Current $3,600 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: instance (a) and (b) deleted a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In trailer #1 employees were exposed to fire and explosion hazards from accumulating deposits of combustible residues from spraying operations, on or about December 14, 2015. Large accumulations of combustible residue were observed on the floor, walls, and cabinets. b) 1190 Lancaster Rd, Manheim PA: Wheel Repair Area - In trailer #2 employees were exposed to fire and explosion hazards from accumulating deposits of combustible residues from spraying operations, on or about December 14, 2015. Large accumulations of combustible residue were observed on the floor, walls, and cabinets. c) 1190 Lancaster Rd, Manheim PA: Wheel Repair Area - In trailer #3 employees were exposed to fire and explosion hazards from accumulating deposits of combustible residues from spraying operations, on or about December 14, 2015. Large accumulations of combustible residue were observed on the floor, walls, and cabinets. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $3600
- — C (S) $6000
- — Z (S) $6000
1910.242 B
- Issued
- Jun 1, 2016
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Employees use an air gun to clean off alloy wheel rims after buffing/grinding them and the compressed air was not reduced to less than 30 p.s.i., on or about December 14, 2015. No abatement certification or documentation required.
Recent events (3)
- — F (S) $3000
- — C (S) $5000
- — Z (S) $5000
1910.305 A04 V
- Issued
- Jun 1, 2016
- Abate by
- Jul 6, 2016
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.305(a)(4)(v): Conductors within 7 feet from the floor, thus considered exposed to physical damage, were not protected: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In the hut, Romex cable running from the circuit breaker at approximately 4 ft - 5 ft above the floor was not protected from physical damage, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $1800
- — C (S) $3000
- — Z (S) $3000
1910.37 B02
- Issued
- Jun 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In the hut, employees were exposed to an egress hazard when there was no exit sign posted on the exit door, on or about December 15, 2015. b) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In each of the trailers, employees were exposed to an egress hazard when there was not an exit sign posted on the exit doors, on or about December 15, 2015. No abatement certification or documentation required.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.107 G07
- Issued
- Jun 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): "NO SMOKING" sign(s) in large letters on contrasting color backgrounds were not conspicuously posted at spraying area(s) and paint storage room(s): a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - Two of the four trailers used for flammable spray painting operations did not have a "No Smoking" sign posted, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.157 G01
- Issued
- Jun 1, 2016
- Abate by
- Jul 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - The employer did not provide an educational program for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting, thus exposing employee's to fire related injuries, on or about December 14, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.304 F01 VIII
- Issued
- Jun 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD": a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In the hut, a circuit panel box with multiple circuit breakers being used as switches for fluorescent lights were not listed and marked "SWD", on or about December 14, 2015. No abatement certification or documentation required.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Jun 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) 1190 Lancaster Rd, Manheim PA; Wheel Repair Area - In the hut, a circuit panel box was blocked by a utility cart, on or about December 14, 2015. No abatement certification or documentation required.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Dent Wizard International Corporation
View Dent Wizard International Corporation's full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341120202.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.