OSHA Inspection: DENT WIZARD INTERNATIONAL CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DENT WIZARD INTERNATIONAL CORPORATION in 7206 BLANCO RD., SAN ANTONIO, TX 78216 (NAICS 811121). OSHA activity number 343833240.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dent Wizard International Corporation — free Get an email when a new federal OSHA severe-injury report for Dent Wizard International Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7206 BLANCO RD.
City
SAN ANTONIO
State
TX
ZIP
78216
Mailing
4710 EARTH CITY EXPRESSWAY, BRIDGETON, MO 63044
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
3000
Ownership type
A

7 citations on file for this inspection.

1910.22 A02

Other-than-serious 1 instance 8 exposed
Issued
Aug 23, 2019
Penalty
Initial $11,366 · Current $6,000 Reduced
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition:    Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, employees were exposed to slip, trip and fall hazards while painting inside the tent where standing water accumulated due to a clogged drain.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $11366

1910.134 D01 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 23, 2019
Abate by
Sep 9, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.134(d)(1)(i): The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker was exposed:  Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, the employer did not select and provide respirators for paint spraying operations with products that contained isocyanates such as, but not limited to, PPG Hardener DCH2015 and Standard Undercoat Hardener EH391.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.134 D01 III

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 23, 2019
Abate by
Nov 1, 2019
Penalty
Initial $0 · Current $8,000
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate respiratory hazards in the workplace to include a reasonable estimate of employee exposure to respiratory hazards and an identification of the contaminant's chemical state and physical form:    Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, the employer did not identify and evaluate the respiratory hazards for employees performing painting operations with PPG products such as, but not limited to, Industries Hardener DCH2015, Deltron 2000 Basecoat DBC-1, Medium Complaint Thinner D8774, and Reducer DT860.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 23, 2019
Abate by
Sep 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, employees were exposed to respiratory hazards while using 3M half-face tight fitting respirators with facial hair obstructing the sealing surface during painting operations where PPG products containing chemicals such as, but not limited to, isocyanates, xylene, toluene, butyl acetate, methylcyclohexane, acetone, and naphtha were used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 III

Other-than-serious 1 instance 8 exposed
Issued
Aug 23, 2019
Abate by
Sep 9, 2019
Penalty
Initial $11,366 · Current $6,000 Reduced
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:    Repair Area Outside Building:  On or about March 7, 2019, and times prior thereto, employees were exposed to chemical hazards while handling products such as, but not limited to, PPG Industries Hardener DCH2015, Deltron 2000 Basecoat DBC-1, Medium Complaint Thinner D8774, and Reducer DT860 without being informed by the employer of the associated hazards of these chemicals, symptoms of exposure, and precautionary measures.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $11366

1910.107 C02

Willful Gravity 10 1 instance 8 exposed
Issued
Aug 23, 2019
Abate by
Sep 9, 2019
Penalty
Initial $132,598 · Current $70,000 Reduced
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet, unless separated from by a partition:    Alaska Tent, #603:  On or about March 4, 2019, and at times prior thereto, employees were exposed to fire hazards while using a Dyna-Glo propane heater inside the tent where PPG flammable products such as, but not limited to, Industrial Hardener DCH2015 and Deltron 2000 Basecoat DBC-1 were used during painting operations.
Recent events (2)
  • — I (W) $70000
  • — Z (W) $132598

1910.107 C06

Willful Gravity 10 2 instances 8 exposed
Issued
Aug 23, 2019
Abate by
Sep 9, 2019
Penalty
Initial $132,598 · Current $70,000 Reduced
29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations:     a). Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, employees were exposed to fire hazards from the use of non-intrinsically safe Phillips fluorescent lights inside the tent where PPG flammable products were applied during painting operations.     b). Alaska Tent, #603:  On or about March 7, 2019, and at times prior thereto, employees were exposed to fire hazards from the use of a non-explosion proof Dayton 24 inch Shutter Mount Exhaust Fan inside the tent where PPG flammable products were applied during painting operations.
Recent events (2)
  • — I (W) $70000
  • — Z (W) $132598

View Dent Wizard International Corporation's full OSHA safety record →