Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & R BUILDERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of M & R BUILDERS, LLC in DOWNING COURT APARTMENTS, BUILDING NO. 1 410 TAYLOR STREET, JACKSON, MS 39216 (NAICS 236116). OSHA activity number 341120509.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & R Builders, LLC — free Get an email when a new federal OSHA severe-injury report for M & R Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
M & R BUILDERS, LLC
Site address
DOWNING COURT APARTMENTS, BUILDING NO. 1 410 TAYLOR STREET
City
JACKSON
State
MS
ZIP
39216
Mailing
P.O. BOX 488, NESBIT, MS 38651
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 15, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems with toeboards, safety net systems or personal fall arrest systems.  (a)  Downing Court Apartment Building No. 1 - On or about December 9, 2015, subcontractor employees accessing ladders between floors and the roof from the second and third floor balconies of Building #1 were exposed to falls to the ground of 10 feet 9 1/4 inches and 21 feet 6 1/2 inches respectively due to the absence of standard guardrails along the unguarded, open-sided proposed second and third floor balconies.  (b)  Downing Court and Taylor Court Apartment Buildings - On or about December 9, 2015, subcontractor employees working on the second and third floor balconies of Downing Court Building #1 and Taylor Court Building #2 were exposed to falls to the ground of 10 feet 9 1/4 inches and 21 feet 6 1/2 inches respectively due to the absence of standard guardrails along those unguarded, open-sided proposed second and third floor balconies.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

1926.501 B11

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 15, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems or personal fall arrest systems:   (a)  Downing Court Apartment Building No. 1 - On or about December 9, 2015 subcontractor employees installing roofing felt and shingles on a steep-sloped roof (6:12 slope) located 30 feet 8.5 inches above the ground were not protected from falling by approved personal fall arrest system(s);.  Instead, employees were wearing rock-climbing waist harnesses and occasionally tethering to a small diameter lifeline without utilizing shock-absorbing lanyards as they moved about the roof.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 15, 2016
Abate by
Mar 17, 2016
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)  Downing Court Building No. 1 - On or about December 9, 2015 three subcontractor employees accessing the roof from a 12 foot aluminum extension ladder situated on the east end of the third floor balcony of Building #1 were exposed to falls to the ground of 21 1/2 to 30 1/2 feet due to the top of the ladder only extending about 1 foot above the upper landing, instead of at least 3 feet above the upper landing.  It was secured against displacement.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

View M & R Builders, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341120509.