Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WATCO COMPANIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WATCO COMPANIES, LLC in 6870 US HWY 42 E GATE 5, GHENT, KY 41045 (NAICS 336611). OSHA activity number 341123685.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Watco Companies, LLC — free Get an email when a new federal OSHA severe-injury report for Watco Companies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6870 US HWY 42 E GATE 5
City
GHENT
State
KY
ZIP
41045
Mailing
6870 US HWY 42 E GATE 5, GHENT, KY 41045
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
58
Ownership type
A

2 citations on file for this inspection.

1910.304 G05

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2016
Abate by
Feb 10, 2016
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Fueling Station- On or about 12/115/15, employees were exposed to electrical hazards when the ground prong on the power supply to the diesel tank was missing.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3400

1910.305 G02 II

Other-than-serious 1 instance 2 exposed
Issued
Jan 29, 2016
Abate by
Feb 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:Note:  Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.  a) Diesel Fuel Tank - On or about 12/15/15, employees were exposed to electrical hazards when temporary power cables were spliced together without retaining the insulating, outer sheath properties and usage characteristics of the  cords being spliced  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Watco Companies, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341123685.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.