BROOKLYN, NY —
OSHA Inspection: MVG HOME IMPROVEMENT CORP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MVG HOME IMPROVEMENT CORP in 142 S. 3RD ST., BROOKLYN, NY 11211 (NAICS 238160). OSHA activity number 341161446.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MVG HOME IMPROVEMENT CORP
- Site address
- 142 S. 3RD ST.
- City
- BROOKLYN
- State
- NY
- ZIP
- 11211
- Mailing
- 133-02 116TH AVE, SOUTH OZONE PARK, NY 11420
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F03
- Issued
- Feb 1, 2016
- Abate by
- Feb 9, 2016
- Penalty
- Initial $2,200 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) North side of building - On or about January 7, 2016 and at times prior thereto, the frame scaffold was not inspected by a competent person prior to employees working on it.
Recent events (2)
- — I (S) $1100
- — Z (S) $2200
1926.451 B01
- Issued
- Feb 1, 2016
- Abate by
- Feb 9, 2016
- Penalty
- Initial $3,080 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) North side of building - On or about January 7, 2016 and at times prior thereto, employees were using a scaffold system for access to the roof and working from the top level of the scaffold. The scaffold platforms were not fully planked, having only half the width of the scaffold planked and at the top level there was a single plank being worked off of. This exposes employees to a fall hazard of approximately 19-22' depending on what platform they are standing.
Recent events (2)
- — I (S) $2000
- — Z (S) $3080
1926.451 E01
- Issued
- Feb 1, 2016
- Abate by
- Feb 9, 2016
- Penalty
- Initial $2,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) North side of building - On or about January 7, 2016 and at times prior thereto, employees were using cross bracing and the end members of the scaffold frames as a means of access.
Recent events (2)
- — I (S) $0
- — Z (S) $2200
1926.451 G01 VII
- Issued
- Feb 1, 2016
- Abate by
- Feb 9, 2016
- Penalty
- Initial $6,160 · Current $3,900 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) North side of building - On or about January 7, 2016 and at times prior thereto, employees were exposed to fall hazards of approximately 22' while working on a scaffold system. No guardrails were in place and there was no personal fall protection being used. The MVG Home Improvement Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1)(vii), which was contained in OSHA inspection number 1071345, citation number 1, item number 2a and was affirmed as a final order on 9-16-2015, with respect to a workplace located at 21-22 74th Street, East Elmhurst, NY 11370.
Recent events (2)
- — I (R) $3900
- — Z (R) $6160
More inspections at MVG Home Improvement Corp