HOUSTON, TX —
OSHA Inspection: ODYSSEY INDUSTRIAL SYSTEMS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ODYSSEY INDUSTRIAL SYSTEMS, LLC in 11669 BRITTMOORE PARK DR., HOUSTON, TX 77041 (NAICS 332710). OSHA activity number 341161727.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ODYSSEY INDUSTRIAL SYSTEMS, LLC
- Site address
- 11669 BRITTMOORE PARK DR.
- City
- HOUSTON
- State
- TX
- ZIP
- 77041
- Mailing
- 11669 BRITTMOORE PARK DR., HOUSTON, TX 77041
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 16
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 D01 II
- Issued
- Apr 19, 2016
- Penalty
- Initial $2,400 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side: On or about January 7, 2016, in the dip tank area, where employees were exposed to fall hazards when accessing the platform for the dip tank without having a stair railing on the open side of the stairs.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
1910.124 G02
- Issued
- Apr 19, 2016
- Abate by
- May 6, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.124(g)(2): Employees who worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation: On or about January 7, 2016, in the dip tank area, where employees were exposed to chemical burn hazards when dipping materials in a dip tank with corrosive chemicals without being provided an emergency shower and eye-wash station.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.124 H03
- Issued
- Apr 19, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.124(h)(3): Employees working with liquids that could burn, irritate, or otherwise harm their skin were not provided with appropriate first-aid supplies that were located near dipping or coating operations. On or about January 7, 2016, in the dip tank area, where employees were exposed to liquids that could burn, irritate, or otherwise harm their skin and were not provided with appropriate first-aid supplies that were located near dipping or coating operations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Apr 19, 2016
- Abate by
- Aug 15, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about January 7, 2016, in the production area where employees were exposed to caught-by and struck-by hazards while performing servicing and or maintenance, such as but not limited to, changing dies and set-up tasks on the following types of equipment: a. Amada Press Brake HDS 1303 b. Amada Press Brake RGM2 3512 c. Amada Punch Press 3610 d. Time Savers Grinders 2100 and 2200
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.178 L02 II
- Issued
- Apr 19, 2016
- Penalty
- Initial $2,000 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. On or about January 7, 2016, in the production area, the employees were exposed to crushed-by hazards when operating power industrial trucks without successfully completing training which consists of formal instruction, practical training, and evaluation of performance.
Recent events (2)
- — I (S) $1260
- — Z (S) $2000
1910.212 A03 II
- Issued
- Apr 19, 2016
- Abate by
- Nov 30, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). On or about January 7, 2016 in the production area, where employees were exposed to caught-in or between hazards while operating the following machines without a point of operation guard or safeguarding device: a. Amada Press Brake HDS 1303 b. Amada Press Brake RGM2 3512
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.253 B04 III
- Issued
- Apr 19, 2016
- Abate by
- May 6, 2016
- Penalty
- Initial $2,000 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1/2 hour. On or about January 7, 2016, in the gas-cylinder storage area, where employees were exposed to fire hazards where oxygen cylinders were stored with acetylene cylinders without a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least 1/2 hour or a minimum distance of 20 feet.
Recent events (2)
- — I (S) $1260
- — Z (S) $2000
1904.39 A02
- Issued
- Apr 19, 2016
- Penalty
- Initial $1,000 · Current $600 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: On or about January 6, 2016, OSHA was notified of an amputation which was not reported within 24 hours of the injury occurring.
Recent events (2)
- — I (O) $600
- — Z (O) $1000
1910.141 D01
- Issued
- Apr 19, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition: On or about January 7, 2016, in the employees bathroom, the washing facilities were not maintained in a sanitary condition.
Recent events (2)
- — I (O) $400
- — Z (O) $400
More inspections at Odyssey Industrial Systems, LLC
View Odyssey Industrial Systems, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341161727.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.