MONSEY, NY —
OSHA Inspection: MALDONADO GROUP, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MALDONADO GROUP, INC. in 23 WOODSIDE PLACE, MONSEY, NY 10952 (NAICS 238130). OSHA activity number 341168391.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MALDONADO GROUP, INC.
- Site address
- 23 WOODSIDE PLACE
- City
- MONSEY
- State
- NY
- ZIP
- 10952
- Mailing
- 128 HECKEL STREET, BELLEVILLE, NJ 07109
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 F06
- Issued
- Jun 9, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: On or about; December 18, 2015 Location: 23 Woodside Place, Monsey, NY 109542 a) Two employees were exposed to electrical hazards by using an ungrounded extension cord to energize a radial saw.
Recent events (1)
- — Z (S) $1200
1926.416 E01
- Issued
- Jun 9, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were being used: On or about; December 18, 2015 Location: 23 Woodside Place, Monsey, NY 109542 a) Two employees were exposed to electrical hazards by using a damaged extension cord to energize a radial saw. Damage included cuts to the outer insulation of the extension cable.
Recent events (1)
- — Z (S) $0
1926.1052 C01 I
- Issued
- Jun 9, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: On or about; December 18, 2015 Location: 23 Woodside Place, Monsey, NY 109542. Two front entry stairs and the stairs to access the second floor. a) Employees used stairs having 4 and 5 risers that did not have at least one handrail to access the building.
Recent events (1)
- — Z (S) $1600
1926.1051 A
- Issued
- Jun 9, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder was not provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided: On or about; December 18, 2015 Location: 23 Woodside Place, Monsey, NY 109542. Residential construction's rear side entry. a) Employees were accessing an elevated entry approximately 34 inches height from the ground where no stairs or ladder was provided, exposing employees to falls.
Recent events (1)
- — Z (S) $1200
More inspections at Maldonado Group, INC.
View Maldonado Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341168391.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.