OSHA Inspection: QUIETAIRE CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUIETAIRE CORPORATION in 505 N. HUTCHESON ST., HOUSTON, TX 77003 (NAICS 333413). OSHA activity number 341168581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quietaire Corporation — free Get an email when a new federal OSHA severe-injury report for Quietaire Corporation is published. One employer, no account, unsubscribe in one click.
Site address
505 N. HUTCHESON ST.
City
HOUSTON
State
TX
ZIP
77003
Mailing
505 N. HUTCHESON ST., HOUSTON, TX 77003
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
May 27, 2016
Abate by
Jul 2, 2016
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative:  a) At the facility, an energy control program that consisted of employee training, energy control procedures and periodic inspections was not established.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.212 A03 II

Serious Gravity 5 2 instances 6 exposed
Issued
May 27, 2016
Abate by
Jul 2, 2016
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a)  At the worksite where a Wysong Press Brake lacked machine guarding to prevent the employees from having any part of their body in the danger zone during the operating cycle.   b)  At the worksite where a Cincinnati shear lacked machine guarding to prevent the employees from having any part of their body in the danger zone during the operating cycle.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

View Quietaire Corporation's full OSHA safety record →