OSHA Inspection: QUIETAIRE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QUIETAIRE CORPORATION in 505 N. HUTCHESON ST., HOUSTON, TX 77003 (NAICS 333413). OSHA activity number 341621506.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quietaire Corporation — free Get an email when a new federal OSHA severe-injury report for Quietaire Corporation is published. One employer, no account, unsubscribe in one click.
Site address
505 N. HUTCHESON ST.
City
HOUSTON
State
TX
ZIP
77003
Mailing
505 N. HUTCHESON ST., HOUSTON, TX 77003
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
19
Ownership type
A

9 citations on file for this inspection.

1910.179 J03

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $3,135 · Current $1,500 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  a)  At the site on or about July 12, 2016, in the  welding area a crane had not been periodically inspected within the past 12 months, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3135

1910.184 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $4,703 · Current $1,526 Reduced
29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used:    a)  At the site on or about July 12, 2016, in the welding area a synthetic web sling that was broken and had been tied back together with a knot was in use, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $1526
  • — Z (S) $4703

1910.184 D

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:  a)  At the site on or about July 12, 2016,  slings being used in the welding area were not inspected for damages or defects prior to use, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 C14

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $2,850 · Current $0 Reduced
29 CFR 1910.184(c)(14): Sling(s) were used without having affixed and legible identification markings:    a)  At the site on or about July 12, 2016, in the welding area a fiber rope sling that did not have affixed identification markings was in use, exposing employee to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2850

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $3,920 · Current $1,000 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    a)  At the site on or about July 7, 2016, openings on a shop fan being used in the welding area were larger than half an inch, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3920

1910.213 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $5,487 · Current $1,000 Reduced
29 CFR 1910.213(g)(1): Swing cutoff saw(s) were not provided with an automatically adjusting hood that completely enclosed the upper half of the saw, the arbor end, and the point of operation at all positions of the saw:    a)  At the site on or about July 12, 2016, an overhead swing saw was not provided with an automatically adjusting hood that completely enclosed the saw at all positions, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $5487

1910.212 A03 II

Repeat Gravity 10 2 instances 2 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $10,974 · Current $10,974
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) In the main shop area, the point of operation of a 60-ton Niagara  press brake, model number 18-36-6-8, serial number 44-741, was not guarded, exposing employees to amputation hazards.  b) In the main shop area, the point of operation of a 140-ton WYSONG  press brake, model number FAB140-168, serial number HPF27-100, was not guarded, exposing employees to amputation hazards.   c) In the main shop area, the point of operation of a 75-ton Chicago press brake, model number 810-C, serial number L-10052, was not guarded, exposing employees to amputation hazards.   d) In the main shop area, the point of operation of a 160-ton Durma press brake, model number E 30160, serial number 7541072963-E, was not guarded, exposing employees to amputation hazards.   e) In the welding area, the point of operation of a RAMCO horizontal band saw was not guarded, exposing employees to amputation hazards.  QuietAire Corporation was previously cited for a violation of this occupational safety and health standard, 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 116858, citation number 1, item number 2 and was affirmed as a final order on June 9, 2016, with respect to a workplace located at 505 N. Hutcheson St. Houston, TX 77003.
Recent events (2)
  • — I (R) $10974
  • — Z (R) $10974

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $440 · Current $0 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i)-(ix) with worksite specific procedures was not established and implemented for required respirator use:    a)  At the site on or about July 12, 2016,  a written respiratory program had not been developed and implemented.  Employees are required to use half-face respirators while spray painting.
Recent events (2)
  • — I (O) $0
  • — Z (O) $440

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Dec 23, 2016
Abate by
Dec 30, 2016
Penalty
Initial $440 · Current $0 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)  At the site on or about July 12, 2016, a written hazard communication program had not been developed, implemented and maintained.
Recent events (2)
  • — I (O) $0
  • — Z (O) $440

View Quietaire Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341621506.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.