OSHA Inspection: NEW CUMBERLAND HOSPITALITY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEW CUMBERLAND HOSPITALITY, INC. in 148 SHERATON DR, NEW CUMBERLAND, PA 17070 (NAICS 721110). OSHA activity number 341169696.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NEW Cumberland Hospitality, INC. — free Get an email when a new federal OSHA severe-injury report for NEW Cumberland Hospitality, INC. is published. One employer, no account, unsubscribe in one click.
Site address
148 SHERATON DR
City
NEW CUMBERLAND
State
PA
ZIP
17070
Mailing
148 SHERATON DRIVE ATTN: DONNA SHIMKO - GENERAL MANAGER, NEW CUMBERLAND, PA 17070
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
37
Ownership type
A

10 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user:  (a) 148 Sheraton Drive, New Cumberland, Pennsylvania - The employer permitted maintenance employees to voluntarily wear North 5500 series elastomeric half-mask air-purifying respirators with N75001L organic vapor cartridges when the employees did maintenance activities such as painting and investigating water leaks.  The employer did not develop and implement any written respiratory protection program, exposing the employee to hazards of inhalation, ingestion, or absorption of contaminants and increased physiological burden, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit-tested or required to use the respirator in the workplace:  (a) 148 Sheraton Drive, New Cumberland, Pennsylvania - The employer permitted maintenance employees to voluntarily wear North 5500 series elastomeric half-mask air-purifying respirators with N75001L organic vapor cartridges when the employees did maintenance activities such as painting and investigating water leaks.  The employer did not provide the employees with a medical evaluation to determine the employees' ability to use the respirator, exposing the employees to an increased physiological burden, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a) 148 Sheraton Drive, New Cumberland, Pennsylvania - The employer permitted maintenance employees to voluntarily wear North 5500 series elastomeric half-mask air-purifying respirators with N75001L organic vapor cartridges when the employees did maintenance activities such as painting and investigating water leaks.  The respirators just laid on work surfaces in the maintenance area where they had exposure to contamination, exposing the employee to hazards of inhalation, ingestion, or absorption of contaminants, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) 148 Sheraton Drive, New Cumberland, Pennsylvania - The employer permitted maintenance employees to voluntarily wear North 5500 series elastomeric half-mask air-purifying respirators with N75001L organic vapor cartridges when the employees did maintenance activities such as painting and investigating water leaks.  The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to the employees, exposing the employees to hazards of inhalation, ingestion, or absorption of contaminants and increased physiological burden, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
May 18, 2016
Abate by
Jul 6, 2016
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from hazards created by open flames:  (a) Laundry - The Huebsch Originators gas drying tumbler operated with the access panel door, located on the top front of the dryer, open, exposing employees to the gas flame on the burner unit, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.303 B02

Serious Gravity 1 2 instances 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Employee Break Room by the Sales Office - The employer used a relocatable power tap (a.k.a., a power strip or surge protector) to power a Haier compact refrigerator.  The UL listing for the power tap specifies use in supplying power to low amperage electronic equipment rather than appliances such as the refrigerator, exposing employees to an electrical hazard, on or about January 8, 2016.  (b) Pool Equipment Closet - A metal junction box, with knockouts on the sides, which supplied electrical wiring to the Hayward pool pump, model K48M2N111, laid on the floor.  The employer did not have this metal knockout box installed in accordance with the box's listing, labeling, or certification in that the employer did not have this knockout box securely and rigidly mounted to the building or other support structure, exposing employees to an electrical hazard, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.303 B08 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 22, 2016
Penalty
Initial $1,785 · Current $1,160 Reduced
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted:  (a) Pool Equipment Closet - The electrical enclosure box marked "Box D Breaker 7," for an Intermatic T100 series mechanical timer switch, hung loosely on the wall just inside the door to the room (on the left side facing this door when standing inside the room), exposing employees to an electrical hazard, on or about January 8, 2016.  Corrected during the inspection.
Recent events (2)
  • — I (S) $1160
  • — Z (S) $1785

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
May 18, 2016
Abate by
Jun 14, 2016
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) Pool Equipment Closet - The working space in front of the electrical panel box, which contained breakers for loads, such as lights and receptacles for the Tent and Outdoor Courtyard, had ladders, ceiling tiles, and pool chemicals stored within it, exposing employees to an electrical hazard, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.303 G02 I

Serious Gravity 1 3 instances 5 exposed
Issued
May 18, 2016
Abate by
Jul 6, 2016
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  (a) Pool Equipment Closet - Live wiring dangled 6 feet 2 inches above the floor, from an unattached elbow fitting on the end of a piece of metal conduit, exposing employees to an electrical hazard, on or about January 8, 2016.  Corrected during the inspection.  (b) Pool Equipment Closet - The door of the enclosure box for the Intermatic T100 series mechanical timer switch remained open, exposing employees to an electrical hazard, on or about January 8, 2016.  Corrected during the inspection.  (c) Laundry - The Huebsch Originators gas drying tumbler and the Cissell gas dryer (right next to the Huebsch drying tumbler) both operated with the access panel doors, located on the top front of these two dryers, open, exposing live wiring and thereby exposing employees to an electrical hazard, on or about January 8, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1910.37 A03

Other-than-serious 1 instance 2 exposed
Issued
May 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed:  (a) Maintenance Shop - The large room in the Maintenance Shop had permanently attached shelving units installed across a door marked with an emergency exit sign, completely obstructing access to this door, on or about January 8, 2016.  Corrected during the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NEW Cumberland Hospitality, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341169696.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.