Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCHAEFER TOOL AND MANUFACTURING CO. INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHAEFER TOOL AND MANUFACTURING CO. INC. in 5844 NORTH 99TH STREET, MILWAUKEE, WI 53225 (NAICS 332116). OSHA activity number 341171437.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schaefer Tool and Manufacturing CO. INC. — free Get an email when a new federal OSHA severe-injury report for Schaefer Tool and Manufacturing CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
5844 NORTH 99TH STREET
City
MILWAUKEE
State
WI
ZIP
53225
Mailing
5844 NORTH 99TH STREET, MILWAUKEE, WI 53225
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
38
Ownership type
A

9 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.    (a) The employer did not ensure that lockout/tagout training was provided for personnel who are being exposed to electrical, pneumatic, hydraulic, and gravitational energy sources on equipment such as but not limited to the Minster Machine Company Press, Press 49, (model number E2-200-72-36, serial number E2-200-13024).
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources:    (a) The employer did not ensure that all energy isolating devices such as locks/tags and blocks were utilized by employees when clearing jams in the Minster Machine Company Press, Press 49, (model number E2-200-72-36, serial number E2-200-13024).
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      (a) On or about January 7th, 2016, the employer did not ensure that the guards on the Minster Machine Company Press, Press 49, (model number E2-200-72-36, serial number E2-200-13024) prevented employees from reaching through and under the guards.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed employees to injury were not guarded:  (a) On or about January 7th, 2016, the employer did not ensure that the point of operation guards on the Minster Machine Company Press, Press 49, (model number E2-200-72-36, serial number E2-200-13024) prevented employees from reaching through and under the guards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:    (a) The employer did not ensure that all guards on the Minster Machine Company Press, Press 49, (model number E2-200-72-36, serial number E2-200-13024) were affixed to the press.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.303 G01 I

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jul 5, 2016
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:  (a) In the press room, two electrical panels were blocked by carts which were being stored directly in front of the panels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.1200 F05 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 5, 2016
Abate by
Jul 29, 2016
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:    (a) At the Brown Boggs Press (model number SC2-200-72-42, serial number 80106) the bottle of machine oil did not contain labels to identify the substance nor the hazards associated with the machine oil.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 5, 2016
Abate by
Jul 29, 2016
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    (a) Employees have not received hazard communication in regards to the global harmonization system for the chemicals they handle, such as but not limited to machine oils and lubricants.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.303 B01

Other-than-serious 1 instance 3 exposed
Issued
Jul 5, 2016
Abate by
Jul 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  (a) An electrical outlet on the Niagra Press, Press 42, (model number BP2-150-72-36, serial number 51773) was damaged and in need of repair.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Schaefer Tool and Manufacturing CO. INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341171437.