PENROSE, CO —
OSHA Inspection: APPLEGATE COLORADO, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of APPLEGATE COLORADO, LLC in 230 SHOOP DR., PENROSE, CO 81240 (NAICS 322299). OSHA activity number 341174407.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPLEGATE COLORADO, LLC
- Site address
- 230 SHOOP DR.
- City
- PENROSE
- State
- CO
- ZIP
- 81240
- Mailing
- 230 SHOOP DR., PENROSE, CO 81240
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 20
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.110 C05 I J
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.110(c)(5)(i)(j): Heat producing equipment shall be located and used so as to minimize the possibility of ignition of combustibles. a) On or about or about January 12, 2016, heat producing equipment (Propane Fuel Salamander) was used in close proximity to combustible materials (Shredded Paper). Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.110 C05 V B
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $2,250
General-duty citation text
29 CFR 1910.110(c)(5)(v)(b): For temporary heating such as curing concrete, drying plaster and similar applications, heaters (other than integral heater-container units) shall be located at least 6 feet from any LP-Gas container. This shall not prohibit the use of heaters specifically designed for attachment to the container or to a supporting standard, provided they are designed and installed so as to prevent direct or radiant heat application from the heater onto the container. Blower and radiant type heaters shall not be directed toward any LP-Gas container within 20 feet. a) On or about January 12, 2016, the employee were operating a heater (Salamander) where the LP-Gas Container was less than 6 feet behind the heater. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2250
- — Z (S) $0
1910.157 C01
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about January 12, 2016, the employer did not ensure fire extinguishers were properly mounted and readily accessible to employees. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.157 G04
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(4): Employees who have been designated to use fire fighting equipment as a part of the emergency action plan were not provided training in the use of appropriate equipment upon initial assignment and at least annually thereafter: (a) On or about January 12, 2016, the employer designated employees to use fire extinguishers and did not ensure that employees were effective trained in the appropriate use at least annually. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C02 I
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $4,500 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) On or about January 12,, 2016, the employer did not ensure the shaft on the receiving end of the bagger (Cube) machine was guarded. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2250
- — Z (S) $4500
1910.219 C04 I
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) On or about January 12,, 2016, the employer did not ensure the Shredding machine shaft end adjacent the main office stairs was guarded. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) On or about January 12, 2016, the employer did not ensure the sprocket wheels and chains on the front and back of the shredding machine were guarded. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B08 I
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted: a) On or about January 12, 2016, the employer did not firmly mount an electrical box, which was used in the bagging area. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.303 G01 V
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(v): Illumination was not provided for all working spaces about service equipment, switchboards, panel boards, and motor control centers installed indoors: a) On or about January 12, 2016, the employer did not ensure the high voltage room had illumination to service equipment. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- May 11, 2016
- Abate by
- May 31, 2016
- Penalty
- Initial $2,700 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about January 12, 2016, the employer did not ensure the loading dock exit route was free and clear of obstruction. The exit route was blocked with several steel gravity conveyors systems and a forklift. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1350
- — Z (S) $2700
More inspections at Applegate Colorado, LLC
View Applegate Colorado, LLC's full OSHA safety record →
More inspections in this industry (NAICS 322299)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341174407.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.