Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DONALDSON COMPANY INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DONALDSON COMPANY INC. in 5200 COYE DRIVE, STEVENS POINT, WI 54481 (NAICS 333413). OSHA activity number 341180883.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Donaldson Company INC. — free Get an email when a new federal OSHA severe-injury report for Donaldson Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
5200 COYE DRIVE
City
STEVENS POINT
State
WI
ZIP
54481
Mailing
5200 COYO DRIVE, STEVENS POINT, WI 54481
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
490
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 8 exposed
Issued
Feb 23, 2016
Abate by
Mar 8, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    a) On or about January 6, 2016 the employee setting transfer arm sensor(s) on the East can draw line was exposed to struck-by and pinch point hazards from the movement of the transfer shuttle and the coil unload when lockout procedural steps were not implemented including but not limited to:     (1) Know the type and magnitude of the energy, the hazard of the energy to be controlled, and the method or means to control the energy,  (2) Turn off and shut down the machine,   (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source,   (4) affix lockout or tagout devices to each energy isolating device,   (5) prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.212 A01

Serious Gravity 10 1 instance 8 exposed
Issued
Feb 23, 2016
Abate by
Apr 15, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about January 6, 2016 employees were exposed to struck-by and pinch point hazards from the automatic movement of the unguarded transfer arm and coil loading function at the loading area on the East Can Draw Line.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

View Donaldson Company INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341180883.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.