Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROTECH AUTO GROUP, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PROTECH AUTO GROUP, INC. in 1101 FOURTH AVENUE, CORAOPOLIS, PA 15108 (NAICS 811198). OSHA activity number 341183606.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Protech Auto Group, INC. — free Get an email when a new federal OSHA severe-injury report for Protech Auto Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1101 FOURTH AVENUE
City
CORAOPOLIS
State
PA
ZIP
15108
Mailing
1101 FOURTH AVENUE, CORAOPOLIS, PA 15108
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
14
Ownership type
A

10 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 11, 2016
Abate by
Apr 15, 2016
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.107(b)(5)(i):  Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained:    a)  Auto body shop, on or about January 15, 2016 - The Binks spray booth did not have a visible gauge or audible alarm installed on the booth.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.107 B05 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 11, 2016
Abate by
Apr 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  a) Auto body shop, January 15, 2016- Space within the Binks spray booth did not have approved automatic sprinklers on the downstream and upstream sides of the filters.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 11, 2016
Abate by
Apr 15, 2016
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   a)  In the main garage, on or about January 15, 2016 - An approved eye wash station capable of providing immediate emergency quick drenching was not available when employees replaced corrosive car batteries.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.1200 E01

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 11, 2016
Abate by
Apr 10, 2016
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1910.1200(e)(1): The employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met:  a) Facility, on or about January 15, 2016 - Employees used hazardous solvents such as but not limited to:  Gunk Engine Cleaner which contained 2-ButxyEthanol; Tec-A-Brake a flammable, which contained acetone, heptanes, xylene and toluene; Brake Fluid which contained triethylene glycol; Limco Final Wash a flammable which contained n-Heptane and tolulene; 3M 36061 Perfect It Ex rubbing compound which contained light petroleum distillates and aluminum oxide; Limco 203 Pre-Paint Cleaner, a flammable which contained VM&P Naptha Stoddard solvent, isopropanol and trimethylbenzene;  and R-Mur 60 a flammable paint reducer which contained butyl acetate, VM&P Naptha and trimethylbenzene.  The employer did not maintain a written hazard communication program.
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1910.1200 G08

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they are readily accessible during each work shift to employees when they are in their work area(s):    a) Facility, on or about January 15, 2016 - Employees used hazardous solvents such as but not limited to:  Gunk Engine Cleaner which contained 2-ButxyEthanol; Tec-A-Brake a flammable, which contained acetone, heptanes, xylene and toluene; Brake Fluid which contained triethylene glycol; Limco Final Wash a flammable which contained n-Heptane and tolulene; 3M 36061 Perfect It Ex rubbing compound which contained light petroleum distillates and aluminum oxide; Limco 203 Pre-Paint Cleaner, a flammable which contained VM&P Naptha Stoddard solvent, isopropanol and trimethylbenzene;  and R-Mur 60 a flammable paint reducer which contained butyl acetate, VM&P Naptha and trimethylbenzene.  The employer did not have the SDS sheets for all the hazardous chemicals used in the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 11, 2016
Abate by
Mar 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): The employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area:    a) Facility, on or about January 15, 2016 -  Employees used hazardous solvents such as but not limited to:  Gunk Engine Cleaner which contained 2-ButxyEthanol; Tec-A-Brake a flammable, which contained acetone, heptanes, xylene and toluene; Brake Fluid which contained triethylene glycol; Limco Final Wash a flammable which contained n-Heptane and tolulene; 3M 36061 Perfect It Ex rubbing compound which contained light petroleum distillates and aluminum oxide; Limco 203 Pre-Paint Cleaner, a flammable which contained VM&P Naptha Stoddard solvent, isopropanol and trimethylbenzene;  and R-Mur 60 a flammable paint reducer which contained butyl acetate, VM&P Naptha and trimethylbenzene.  Employees were not provided hazard communication training on physical and hazardous properties of the solvents.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Mar 11, 2016
Abate by
Apr 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators were required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures:  a)  In the auto body shop, on or about January 15, 2016 - The employer implemented a mandatory respiratory program for employees who wore 1/2 face tight fitting respirators during spray painting.     A written respiratory protection program was not established and implemented within the worksite.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
Mar 11, 2016
Abate by
Apr 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace:    a) In the auto body shop, on or about January 15, 2016 - Employees were not provided medical evaluations when required to use 1/2 face tight fitting respirators during spray painting.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 2 exposed
Issued
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.  a)  In the auto body shop, on or about January 15, 2016 - Employees who wore 1/2 face tight fitting respirators during spray painting were not provided a fit test prior to initial use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 14 exposed
Issued
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): The employer did not assure that portable fire extinguishers were subjected to an annual maintenance check:    a)  Facility, on or about January 15, 2016 - The fire extinguishers in the garage and auto body shop had not been certified and inspected since 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Protech Auto Group, INC.'s full OSHA safety record →