AMORY, MS —
OSHA Inspection: NAUTIC STAR, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NAUTIC STAR, LLC in 500 WATERWAY DRIVE, AMORY, MS 38821 (NAICS 336612). OSHA activity number 341184588.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAUTIC STAR, LLC
- Site address
- 500 WATERWAY DRIVE
- City
- AMORY
- State
- MS
- ZIP
- 38821
- Mailing
- P.O. BOX 26, AMORY, MS 38821
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 220
- Ownership type
- A
Citations
20 citations on file for this inspection.
1910.106 E02 IV A
- Issued
- Jun 1, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not kept in covered containers when not actually in use: (a) Lamination Staging Area - On or about January 27, 2016 55 gallon drums containing flammable gel coat residue were not covered.
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.106 E03 V A
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.106(e)(3)(v)(a): Areas as defined in paragraph (e)(3)(i) of this section using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area. This was not accomplished by natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building. Provision was not made for introduction of makeup air in such a manner as not to short circuit the ventilation. Ventilation was not arranged to include all floor areas or pits where flammable vapors may collect. (a) Lamination Mixing Room - On or about January 27, 2016 the mixing room did not have mechanical ventilation or adequate natural ventilation.
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.107 B03
- Issued
- Jun 1, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, if combustible, was not covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues. (a) R & D Paint Booth - On or about January 27, 2016 the paint booth floors were covered with combustible paper. The paint booth walls were covered with plastic shrink wrap. The shrink wrap did not provide static dissipation and the shrink wrap did not have a maximum breakdown voltage of 4 kV to prevent accumulation of a hazardous static discharge. (b) Lamination Molding Paint Area - On or about January 27, 2016 the paint booth floors were covered with combustible paper. The paint booth walls were covered with plastic shrink wrap. The shrink wrap did not provide static dissipation. The shrink wrap did not have a maximum breakdown voltage of 4 kV to prevent accumulation of a hazardous static discharge
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.107 B05 IV
- Issued
- Jun 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $3,825 · Current $2,600 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: (a) R & D Paint Booth - On or about January 27, 2016 the paint booth did not have a sprinkler system.
Recent events (2)
- — I (S) $2600
- — Z (S) $3825
1910.107 C06
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: (a) Facility - On or about January 27, 2016 the lighting, electrical panels, receptacles and equipment in the following locations were not rated for Class 1, Division 1 areas. (i) R & D Spray Area - On or about January 27, 2016 electrical receptacles, electrical panels on the outside of the paint booth, bench grinder and battery chargers on work table within 20 feet of the spray area were not explosion proof. (ii) Lamination Small Parts - On or about January 27, 2016 electrical panels, electrical disconnects and exhaust fan on the wall between the ventilation systems were within 20 feet of the spray area and were not explosion proof. (ii) Lamination Molding Paint Booths - On or about January 27, 2016 fluorescent light fixtures and wiring were not explosion proof. Gel coat residue was on the light fixtures and on the wall at or above the light fixtures. (iv) Mixing Room - On or about January 27, 2016 fluorescent light fixture, orange extension cord and radio was not explosion proof.
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.107 C09 I
- Issued
- Jun 1, 2016
- Abate by
- Aug 9, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.107(c)(9)(i): All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) or aerated solids were not properly electrically grounded in an effective and permanent manner: (a) R & D - On or about January 27, 2016 Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded. (b) Lamination - On or about January 27, 2016 the Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded. (c) Offshore - On or about January 27, 2016 the Magnum Venus Paint (MVP) sprayers and chopper sprayers were not grounded.
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.107 G02
- Issued
- Jun 1, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $6,300 · Current $4,380 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of non-sparking material. (a) Lamination Molding Painting Area - On or about January 27, 2016 painting area number 4 had an excessive amount of gel coat build-up in the back of the room.
Recent events (2)
- — I (S) $4380
- — Z (S) $6300
1910.147 C07 I
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $3,060 · Current $2,080 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Throughout Facility - On or about January 28, 2016 the employer failed to train all affected and authorized maintenance employees on the energy control program to ensure they understand the hazards and have the skills required for the safe application and removal of energy controls.
Recent events (2)
- — I (S) $2080
- — Z (S) $3060
1910.304 G05
- Issued
- Jun 1, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $2,295 · Current $1,660 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. (a) Offshore - On or about January 15, 2016 an extension cord used for a handheld DeWalt buffer did not have a grounding prong.
Recent events (2)
- — I (S) $1660
- — Z (S) $2295
1910.305 A02 IX
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $3,060 · Current $2,090 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. (a) Store, Parts Room - On or about January 27, 2016 light fixtures above storage racks were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard.
Recent events (2)
- — I (S) $2090
- — Z (S) $3060
1910.305 B02 I
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $3,060 · Current $2,090 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Employee Break Rooms - On or about January 28, 2016 two electrical outlets used to supply power for the two Coca-Cola vending machines were not protected from electrical shock by the use of cover plates.
Recent events (2)
- — I (S) $2090
- — Z (S) $3060
1910.305 G01 IV A
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $2,295 · Current $1,660 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure (a) Throughout Building - On or about January 28, 2016 electrical extension cords were being used instead of permanent wiring to supply power to power strips.
Recent events (2)
- — I (S) $1660
- — Z (S) $2295
1910.305 G01 IV B
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: (a) Paint Room Adjacent to Forman's Office - On or about January 27, 2016 the overhead electrical door power cord is fed through a hole in the metal wall.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $4,590 · Current $3,220 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Throughout Facility - On or about January 28, 2016 employees exposed to hazardous chemicals such as, but not limited to, vinylester gel coat, resin and organic peroxide had not received hazard communication training.
Recent events (2)
- — I (S) $3220
- — Z (S) $4590
1910.159 C10
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained: (a) Material Storage Room - On or about January 29, 2016 material stored on top storage rack was within the 18 inches minimum vertical clearance of the automatic sprinkler head.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 A04
- Issued
- Jun 1, 2016
- Abate by
- Aug 29, 2016
- Penalty
- Initial $765 · Current $100 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) Throughout Building - On or about January 28, 2016 employees operating electrical hand trucks that have been modified without the manufacturer's prior written approval.
Recent events (2)
- — I (O) $100
- — Z (O) $765
1910.303 G01
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Lamination, Small Parts Spray Area - On or about January 28, 2016 employees did not have ready access to the electrical panels in case of an emergency. The electrical panels were covered with plastic shrink wrap and two 55 gallon drums were against the panels.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 B03 II C 3
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug were not visually inspected before use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage, and equipment found damaged or defective was not removed from use until repaired: (a) Offshore - On or about January 15, 2016 extension cords for the hand held buffers had torn outer insulation throughout the length of the cords.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 1, 2016
- Abate by
- Jul 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. (a) Lamination RTM - On or about January 27, 2016 Toyota electric hand power cord plug did not have strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Jun 1, 2016
- Abate by
- Jul 1, 2016
- Penalty
- Initial $765 · Current $100 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier, signal word, hazard statement(s), pictogram(s), precautionary statement(s) and name, address, and telephone number of the chemical manufacturer, importer, or other responsible party. (a) Lamination RTM Resin Transfer Mold - On or about January 27, 2016 a 5 gallon bucket containing scrap gel coat was not labeled.
Recent events (2)
- — I (O) $100
- — Z (O) $765
More inspections at Nautic Star, LLC
View Nautic Star, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336612)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341184588.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.