Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARIANA RESORT & SPA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MARIANA RESORT & SPA in ZEN TEPPANYAKI RESTAURANT COCONUT STREET, GARAPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 341191906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mariana Resort & SPA — free Get an email when a new federal OSHA severe-injury report for Mariana Resort & SPA is published. One employer, no account, unsubscribe in one click.
Site address
ZEN TEPPANYAKI RESTAURANT COCONUT STREET, GARAPAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
P.O. BOX 500527, SAIPAN, MP 96950
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
160
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 17, 2016
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:     a) On January 21, 2016 at the backside of the building, a 4 ft. fluorescent ceiling light fixture used as temporary lighting, was not installed and used in accordance with instructions included in the listing, labeling, or certification.  An employee was exposed to accidental contact with live electrical parts.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1926.405 A02 II E

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 17, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:  a) On January 21, 2016 at the backside of the building, the 4 ft. fluorescent light ceiling fixture used for temporary lighting was not provided with a cover to prevent accidental breakage and/or contact.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 D

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 17, 2016
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1926.405(d): A panelboard was not dead front.  a) On January 21, 2016 at the backside of the building, the employer did not ensure that the employee was protected against electrical hazards by ensuring that the 100 AMP power panel was provided with a dead front.