SAIPAN, MP —
OSHA Inspection: MARIANA RESORT & SPA
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MARIANA RESORT & SPA in ZEN TEPPANYAKI RESTAURANT COCONUT STREET, GARAPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 341191906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARIANA RESORT & SPA
- Site address
- ZEN TEPPANYAKI RESTAURANT COCONUT STREET, GARAPAN
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- P.O. BOX 500527, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 160
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- Feb 17, 2016
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On January 21, 2016 at the backside of the building, a 4 ft. fluorescent ceiling light fixture used as temporary lighting, was not installed and used in accordance with instructions included in the listing, labeling, or certification. An employee was exposed to accidental contact with live electrical parts.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1926.405 A02 II E
- Issued
- Feb 17, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) On January 21, 2016 at the backside of the building, the 4 ft. fluorescent light ceiling fixture used for temporary lighting was not provided with a cover to prevent accidental breakage and/or contact.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 D
- Issued
- Feb 17, 2016
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1926.405(d): A panelboard was not dead front. a) On January 21, 2016 at the backside of the building, the employer did not ensure that the employee was protected against electrical hazards by ensuring that the 100 AMP power panel was provided with a dead front.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
More inspections at Mariana Resort & SPA
View Mariana Resort & SPA's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341191906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.