Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCE INDUSTRIES GROUP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ADVANCE INDUSTRIES GROUP in 3636 WEST 58TH STREET, CLEVELAND, OH 44102 (NAICS 332312). OSHA activity number 341192698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advance Industries Group — free Get an email when a new federal OSHA severe-injury report for Advance Industries Group is published. One employer, no account, unsubscribe in one click.
Site address
3636 WEST 58TH STREET
City
CLEVELAND
State
OH
ZIP
44102
Mailing
3636 WEST 58TH STREET, CLEVELAND, OH 44102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.106 D03 II A

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 22, 2016
Abate by
Mar 26, 2016
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.106(d)(3)(ii)(a): Metal cabinets were not deemed to be in compliance as they were not constructed with the bottom, top, door, and sides of cabinet at least No. 18 gage sheet iron and double walled with 1 1/2-inch air space; the joints riveted, welded, or made tight by some equally effective means; the door provided with a three-point lock; and/or the door sill raised at least 2 inches above the bottom of the cabinet:  On or about January 21, 2016 the flammable paints and solvents in use in the paint booth area were stored in a two door file cabinet that does not meet the requirements as described in this section.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.107 B06

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 22, 2016
Abate by
Mar 1, 2016
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.107(b)(6): Frontal area. Each spray booth having a frontal area larger than 9 square feet did not have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening:  On or about January 21, 2015, the paint booth nearest the paint storage area, did not have the required metal deflector or curtain present as required.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.107 B09

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 22, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9):  A clear space of not less than 3 feet on all sides was not maintained free from storage or combustible combustible construction:  On or about January 21, 2016, in the painting area the spray booth(s) did not have all sides of the booth cleared as required where other equipment and materials were stacked or stored by the outside walls of the booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 22, 2016
Abate by
Mar 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(1): Conformance. All electrical equipment, open flames and other sources of ignition did not conform to the requirements of this paragraph:  On or about January 21, 2015, the paint booth, nearest the paint storage cabinet, had a transparent plastic sheeting covered electrical apparatus of an unknown rating at the face of the booth, pointing inwards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Serious Gravity 1 1 instance 30 exposed
Issued
Feb 22, 2016
Abate by
Mar 26, 2016
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.1200(h)(3)(iv):  Employee training did not include at least an explanation of the labels received on shipped containers and the workplace labeling system used by their employer and the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information:   On or about January 21, 2016,  the employer had not provided the detailed training as required for such hazardous materials/chemicals as, but not limited to the paints, coatings, solvents, and lubricants in use on site.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 22, 2016
Abate by
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i):  The employer did not provide Appendix D of this section when respirators are provided for use on site:  On or about January 21, 2016, the employer had not provided the information as required for the voluntary use of respiratory protection within the facility including, but not limited to the full face tight fitting respirator in use in the paint spray booth(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Advance Industries Group's full OSHA safety record →