BOISE, ID —
OSHA Inspection: MONSTER FRAMING LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MONSTER FRAMING LLC in 4304 ALEUT, BOISE, ID 83709 (NAICS 236115). OSHA activity number 341195170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONSTER FRAMING LLC
- Site address
- 4304 ALEUT
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 5007 LATHROP PL., CALDWELL, ID 83607
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Apr 4, 2016
- Abate by
- Apr 28, 2016
- Penalty
- Initial $5,280 · Current $5,280
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) On the north side of the structure: On January 20, 2016 and at times prior thereto employees engaged in roofing and framing were exposed to fall hazards of 10.1 feet onto construction debris. Employer was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR Standard that was contained in OSHA Inspection 993435, Citation 1, Item 1a, issued on 10/9/2014; Final order date of 10/24/2014 with respect to the work site on the corner of Pine Tree Village Town Homes , Boise, Idaho. Note: Abatement certification IS required for this item.
Recent events (1)
- — Z (R) $5280
1926.405 G02 IV
- Issued
- Apr 4, 2016
- Abate by
- Apr 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Front of structure, on job site: On January 20, 2016 an electrical cord which lacked strain relief was used to connect to a 240v electrical box. Note: Abatement certification IS required for this item.
Recent events (1)
- — Z (O) $0
More inspections at Monster Framing LLC
View Monster Framing LLC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341195170.