OSHA Inspection: YESAC CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of YESAC CORP. in 40 YESAC DRIVE, TALLASSEE, AL 36078 (NAICS 336399). OSHA activity number 341196871.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Yesac Corp. — free Get an email when a new federal OSHA severe-injury report for Yesac Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
YESAC CORP.
Site address
40 YESAC DRIVE
City
TALLASSEE
State
AL
ZIP
36078
Mailing
40 YESAC DRIVE, TALLASSEE, AL 36078
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
100
Ownership type
A

11 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 18, 2016
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:     a)  Production Area; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate a Shear with unguarded hold downs.
Recent events (1)
  • — Z (S) $2975

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 18, 2016
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury was not guarded:   a) Production Area; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate a Spartan Hercules 330 horizontal band saw that did not have the unused portion of the cutting blade guarded.
Recent events (1)
  • — Z (S) $2975

1910.217 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals:   a) Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to potential crushing and amputation hazards in that the pedal mechanism was not protected to prevent accidental operation from falling/moving objects or by accidental stepping on the pedal.
Recent events (1)
  • — Z (S) $2975

1910.217 B08 III

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(8)(iii): All mechanical power press controls shall incorporate a type of drive motor starter that will disconnect the drive motor from the power source in event of control voltage or power source failure, and require operation of the motor start button to restart the motor when voltage conditions are restored to normal.  a) Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that an employee was operating a mechanical power press that had the drive motor wired directly through a switch and not a drive motor starter that would disconnect the drive motor in the event of power source failure.
Recent events (1)
  • — Z (S) $0

1910.217 B08 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(8)(iv): Voltages higher than 120 volt A.C. that were necessary for operation of mechanical power press(es) or control mechanisms of mechanical power presses were not isolated from control mechanisms handled by the operator:  a) Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that the operator had to manually operate a mechanical 220 volt 3 phase breaker switch to apply power to the press drive motor.
Recent events (1)
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):  a) Production Area - Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to potential crushing and amputation hazards in that the die area was not guarded to prevent employees from sticking their hands / arms into the point of operation.
Recent events (1)
  • — Z (S) $0

1910.217 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i): Records of mechanical power press inspections and the maintenance work performed were not maintained:  a) Production Area - Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to potential crushing and amputation hazards in that employees were alllowed to operate a mechanical power press that the employer had not maintained a certification record of required inspections.
Recent events (1)
  • — Z (S) $0

1910.219 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv):    a) Production Area - Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that the power press had an unguarded flywheel that was within 4 feet of the floor.
Recent events (1)
  • — Z (S) $2975

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 18, 2016
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)  Production Area; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate a metal cutting chop saw that had an unguarded pulley.
Recent events (1)
  • — Z (S) $2380

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   a)  Production Area; On or about January 21, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate a metal cutting chop saw that had an unguarded belt.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 8, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:  a) Production Area - Mechanical Power Press; On or about January 21, 2016 and at times prior thereto the employer exposed employees to electrical hazards in that employees were using an unguarded 220 VAC 3 Phase breaker with exposed live terminals to turn the power on and off to the mechanical power press.