MCKINNEY, TX —
OSHA Inspection: T.Y.G. PRODUCTS, L.P.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of T.Y.G. PRODUCTS, L.P. in 1800 NORTH MCDONALD STREET, MCKINNEY, TX 75071 (NAICS 332119). OSHA activity number 341231058.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T.Y.G. PRODUCTS, L.P.
- Site address
- 1800 NORTH MCDONALD STREET
- City
- MCKINNEY
- State
- TX
- ZIP
- 75071
- Mailing
- 1800 NORTH MCDONALD STREET, MCKINNEY, TX 75071
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 125
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Employer did not ensure employees performing unjamming operations utilize energy control procedures when conducting lockout tagout operations on equipment of Paint Line 1. b) Employer did not ensure employees performing services and maintenance operations utilize energy control procedures when conducting lockout tagout operations on equipment of Paint Line 1.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.147 C04 II
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec: a) The employer did not ensure the energy control procedures outline the scope and authorization of employees performing lockout tagout on Paint Line 1.
Recent events (2)
- — I (S) $6300
- — Z (S) $6300
1910.147 C05 II
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices did not meet the requirements of 29 CFR 1910.147: a) The employer did not ensure a tagout device used on Paint Line 1 was attached in a manner to prevent inadvertent or accidental removal. b) The employer did not ensure a tagout device used to lockout out equipment on Paint Line 1 identified the identity of the employee.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.147 C07 I
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) Employer did not ensure affected employees were instructed in the purpose and use of the energy control procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1910.147 C06 I
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Employer did not conduct a periodic inspection of the energy control procedure on Paint Line 1.
Recent events (2)
- — I (S) $6300
- — Z (S) $6300
More inspections at T.Y.G. Products, L.P.
View T.Y.G. Products, L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 332119)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341231058.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.