DALLAS, TX —
OSHA Inspection: DALLAS U.S.A FOODS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DALLAS U.S.A FOODS, INC. in 1880 LONE STAR DR., DALLAS, TX 75212 (NAICS 311615). OSHA activity number 341238640.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DALLAS U.S.A FOODS, INC.
- Site address
- 1880 LONE STAR DR.
- City
- DALLAS
- State
- TX
- ZIP
- 75212
- Mailing
- 1880 LONE STAR DR., DALLAS, TX 75212
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 125
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.36 D01
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $6,300 · Current $3,780 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) This violation occurred at the back of the building on the north wall, east corner, where an emergency exit door was dead bolted and locked.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.36 G02
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: (a) This violation occurred in the processing area on the east wall, where an emergency exit access was blocked by a pallet. (b) This violation occurred at the outbound dock area, where an emergency exit access was blocked by pallets.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.147 C01
- Issued
- Jul 29, 2016
- Abate by
- Sep 22, 2016
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) This violation occurred on the mezzanine level, at the Russell ice making machine, where the employer did not implement energy control procedures for employees unclogging the machine exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.176 B
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $3,600 · Current $2,160 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: (a) This violation occurred in the cooler where drive-in racking systems were used to hold palletized product and due to design the racks only held onto the outer edge of the pallets exposing employees to struck-by hazard in the event a pallet broke. (b) This violation occurred in the freezer where drive-in racking systems were used to hold palletized product and due to design the racks only held onto the outer edge of the pallets exposing employees to struck-by hazard in the event a pallet broke.
Recent events (2)
- — I (S) $2160
- — Z (S) $3600
1910.212 A02
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) This violation occurred on the mezzanine level where the cover to the ice machine was open exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.303 B02
- Issued
- Jul 29, 2016
- Abate by
- Aug 4, 2016
- Penalty
- Initial $2,700 · Current $4,500
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) This violation occurred in the processing area where a job made extension cord consisting of a plastic permanent mount junction box, a dual receptacle, wiring, and an end-plug was being used to power a scale and a radio exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $4500
- — Z (S) $2700
1910.305 B01 II
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: (a) This violation occurred at the north wall in the processing area next to the entrance to the training room where an electrical pull box was found with a knock out missing exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1910.305 B02 I
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $2,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) This violation occurred on the north wall directly behind the Hotsy hot water pressure machine located up on the mezzanine where a pull box was found without a cover exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2700
1910.304 B03 I
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $4,500 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel: (a) This violation occurred in the processing area where 18 dual-wall receptacles were found not equipped with ground fault circuit interrupter protection exposing employees in a wet area to an electrical hazard.
Recent events (2)
- — I (S) $2700
- — Z (S) $4500
1910.305 E01
- Issued
- Jul 29, 2016
- Abate by
- Aug 10, 2016
- Penalty
- Initial $2,700 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Metallic cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not mounted so that there was at least 6.35-mm (0.25-in) airspace between the enclosure and the wall or other supporting surface: (a) This violation occurred at the North wall in the processing area next to the entrance to the training room where an electrical pull box was missing a knock out exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2700
More inspections at Dallas U.S.A Foods, INC.
View Dallas U.S.A Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311615)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341238640.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.