Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: 3M COMPANY

Fatality or catastrophe inspection · Health discipline

On , OSHA opened a fatality or catastrophe health inspection of 3M COMPANY in 1301 LOWELL STREET, ELYRIA, OH 44035 (NAICS 326199). OSHA activity number 341251551.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 3M Company for free Get an email when a new federal OSHA severe-injury report for 3M Company is published. One employer, no account, unsubscribe in one click.
Establishment
3M COMPANY
Site address
1301 LOWELL STREET
City
ELYRIA
State
OH
ZIP
44035
Mailing
1301 LOWELL STREET, ELYRIA, OH 44035
Inspection type
Fatality or catastrophe (M)
Scope
Partial (B)
Discipline
Health
Advance notice
Yes
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
155
Ownership type
Private (A)

7 citations on file for this inspection.

1910.132 D01 I

Deleted Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazards:       (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML #2 production equipment wore electrical protective gloves to protect from electrical shock.  Voltage in excess of 500 volts, AC single phase, was supplied to the electrodes of the production line.  Employees operating the production equipment were exposed to electrical shock hazards in that the employer provided the employees with gloves that, when new, were rated for a maximum of 500 volts.  Employees were at risk of electrical shock from using gloves that were not rated for the supplied voltage.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.137 C02 VIII

Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Penalty
Initial $0 · Current $7,000
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests. Test voltages and/or the maximum intervals between tests were not conducted in accordance with Table I-4 and Table I-5.           (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that electrical protective gloves used by employees operating the CML #1 and CML #2 production processes were tested every 6 months after issue and after use without protectors.  Electrical protective gloves were used by employees for several years without being tested and without protectors.  Employees were are at risk of electrical shock from using gloves with compromised insulating properties.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $0

1910.335 A01 III

Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Abate by
Jul 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(iii):  The insulating capability of protective equipment was subject to damage during use and the insulating material was not protected:         (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML#2 production processes used protective equipment over the electrical protective gloves while working on or near the production equipment.  There were numerous sharp corners and edges on the production lines which increased the risk of the insulating gloves becoming damaged.  Employees using damaged electrical gloves would be at risk of electrical shock from the exposed energized conductors.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.332 B01

Deleted Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Abate by
Jul 29, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:       (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML #2 production equipment were trained in the safety related work practices that pertained to their job.  Employees routinely worked near exposed, energized electrical conductors, terminals, and electrodes and were unaware of the requirement for electrical protective gloves to be tested at least every 6 months, were not aware that the insulation of the electrical protective gloves was to be protected from damage through the use of protectors, and that the gloves used to protect from shock hazard were rated for a maximum voltage which was less than the applied voltage to the electrodes on the CML. Employees were at risk of electrical shock from using gloves that were not appropriate for the hazards in the workplace.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.333 A

Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Abate by
Jul 29, 2016
Penalty
Initial $0 · Current $7,000
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:         (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML #2 production equipment followed safe related work practices.  Employees operating the CML #1 and CML #2 processes equipment routinely approached within 6 inches of exposed, energized conductors and were not protected from electrical shock.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $0

1910.335 A01 I

Deleted Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Abate by
Jul 29, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:           (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML#2 production processes were protected from electrical shock.  Employees routinely worked near exposed energized electrical conductors without the benefit of having protective insulated sleeves.  Employee's arms were at risk of coming in contact with the exposed conductors exposing employees to electric shock hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.335 A02 II

Serious Gravity 10 1 instance 16 exposed
Issued
Jul 20, 2016
Abate by
Jul 29, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.335(a)(2)(ii): Protective shields, protective barriers, or insulating materials were not used to protect each employee from shock, burns, or other electrically related injuries while that employee was working near exposed energized parts which might accidentally contacted:         (a)  3M Company, 1301 Lowell Street, Elyria, Ohio:  On or about February 13, 2016, the employer did not ensure that employees operating the CML #1 and CML#2 production processes were protected from coming into contact with the exposed, energized electrical wires, terminals, and electrodes on the CML #1 and CML#2 production lines.  Employees routinely worked near the energized parts in the cook zones of the lines and were at risk of electric shock.
Recent events (2)
  • · I (S) $7000
  • · Z (S) $7000

View 3M Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341251551.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.