On , OSHA opened a planned safety inspection of SILVER REEF CASINO in 4876 HAXTON WAY, FERNDALE, WA 98248 (NAICS 721120). OSHA activity number 341254407.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Silver Reef Casino for free Get an email when a new federal OSHA severe-injury report for Silver Reef Casino is published. One employer, no account, unsubscribe in one click.
Establishment
SILVER REEF CASINO
Site address
4876 HAXTON WAY
City
FERNDALE
State
WA
ZIP
98248
Mailing
4876 HAXTON WAY, FERNDALE, WA 98248
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
675
Ownership type
Private (A)

16 citations on file for this inspection.

1910.101 B

Serious Gravity 1 2 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $1,795 Reduced
29 CFR 1910.101(b):  Section 3.4.4, Compressed Gas Association Pamphlet P11965, as incorporated by reference in Sec. 1910.6: Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over:     a) Basement, where unsecured compressed gas cylinders included:     1. Banquet Storage, where one helium compressed gas cylinder was stored in the aisle way.    2. Banquet Storage Cage 4, where three carbon dioxide compressed gas cylinders and one N.O.S carbon dioxide compressed gas cylinder were stored in the aisle way.
Recent events (2)
  • · I (S) $1795
  • · Z (S) $2295

1910.147 C04 I

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Facilities Maintenance, where no written procedures had been developed. Maintenance personnel performed preventative maintenance and repairs on equipment including, but not limited to, florescent light fixtures, 230 volt commercial grade garbage disposals, washing machines, and dryers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2295

1910.147 C06 I

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Facilities Maintenance, where an annual review of the lockout tag out program was not conducted. Maintenance personnel performed preventative maintenance and repairs on equipment including, but not limited to, florescent light fixtures, 230 volt commercial grade garbage disposals, washing machines, and dryers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C06 I C

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  a) Facilities Maintenance, where maintenance personnel performed preventative maintenance and repairs on equipment including, but not limited to, florescent light fixtures, 230 volt commercial grade garbage disposals, washing machines, and dryers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C06 II

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a) Facilities Maintenance, where maintenance personnel performed preventative maintenance and repairs on equipment including, but not limited to, florescent light fixtures, 230 volt commercial grade garbage disposals, washing machines, and dryers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C07 IV

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  a) Facilities Maintenance, where the employer did not certify that employee training had been provided and was up to date. Maintenance personnel performed preventative maintenance and repairs on equipment including, but not limited to, florescent light fixtures, 230 volt commercial grade garbage disposals, washing machines, and dryers.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $1,795 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a) Facilities Maintenance Shop, where the abrasive wheel on the Foremost Tools bench grinder was not equipped with a tongue guard.
Recent events (2)
  • · I (S) $1795
  • · Z (S) $2295

1910.242 B

Serious Gravity 5 1 instance 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $3,060 · Current $1,795 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:    a) Facilities Maintenance, where compressed air set at 110 p.s.i. was used to clean laundry equipment including the Ironer Folder.
Recent events (2)
  • · I (S) $1795
  • · Z (S) $3060

1910.303 B02

Serious Gravity 1 8 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:    a) Facility, where electrical equipment not used as listed or labeled included:    1. Facilities Maintenance Office, where a relocatable power tap was used to supply power to appliances including the Avanti refrigerator.    2. Facilities Maintenance Shop, where a job made extension cord (handy box) was used to test 277 volt hotel room air conditioning units.    3. Basement Slots Department, where a yellow extension cord plugged into an orange extension cord was daisy chained with the Tripp-Lite relocatable power tap and used to supply power to APC back-up units.    4. Slots Department Reception Desk, where a relocatable power tap was used to supply power to appliances including the Comfort Zone floor heater. (Item Corrected)    5. Housekeeping Office Desk #1, where a relocatable power tap was permanently mounted to the desk frame, daisy chained with an orange extension cord, and used to supply power to the computer. (Item Corrected)    6. Housekeeping Office Desk #2, where a relocatable power tap was permanently mounted to the desk frame, daisy chained with an orange extension cord, and used to supply power to the computer. (Item Corrected)    7. Housekeeping Office Radio Charging Table, where two relocatable power taps were daisy chained and used to supply power to the Motorola battery charger. (Item Corrected)    8. Laundry Room, where a relocatable power tap was used to supply power to appliances including the Magic Chef refrigerator. (Item Corrected)
Recent events (2)
  • · I (S) $2295
  • · Z (S) $2295

1910.305 G01 IV A

Serious Gravity 1 3 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:    a) Facility, where flexible cords used a substitute for fixed wiring included:    1. Forklift Shed, where a yellow extension cord was used to supply power to the overhead florescent light fixture.     2. Housekeeping Department, where an orange extension cord was used to supply power to the Brothers sewing machine. (Item Corrected)     3. Accounting Department, where a brown extension cord was used to supply power to appliances including; the Black and Decker coffee maker, the Keurig coffee maker, and the Clover water cooler.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2295

1910.305 G01 IV D

Serious Gravity 1 1 instance 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:     a) Forklift Shed, where the yellow extension cord used to supply power to the overhead florescent light fixture was fastened to the wall and ceiling of the shed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   a) Accounting, where the outlet used to energize the refrigerator and an extension cord was not equipped with a faceplate.
Recent events (2)
  • · I (S) $2295
  • · Z (S) $2295

1910.305 J01 IV

Serious Gravity 1 1 instance 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lamp holders or other electrical parts:  a) Power Washing Area, where a receptacle located outdoors was not marked for wet or damp locations and was not equipped with a cover.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $2,295 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:     a) Facilities Maintenance Shop, where unused openings on energized electrical equipment not equipped with covers included:     1. Circuit panel LS-1 had an uncovered knock-out on the lower right side of the cabinet.     2. Circuit panel LS-3, where the opening beneath the 20 amp AC Test Plugs breaker was not covered.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2295

1910.37 B02

Other-than-serious 3 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":  a) Facility, where the designated emergency exit doors not equipped with exit signs included:  1. Back of Buffet, exit discharge door that opened into the parking lot.   2. Stairwell #2, exit discharge door that opened into the exterior walkway.   3. Third Floor North Tower, double doors that opened into the exit access.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 40 exposed
Issued
Mar 29, 2016
Abate by
May 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage:  a) Facility, where space in front of circuit panels used for storage included:  1. Facilities Maintenance Office, where the Avanti refrigerator was stored in front of panel EP3.  2. Pool Maintenance Room, where items including one trash can and three five gallon buckets were stored in front of panel 3LD.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Silver Reef Casino's full OSHA safety record →