Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIEZO KINETICS, INC.

Monitoring inspection · Health discipline

On , OSHA opened a monitoring health inspection of PIEZO KINETICS, INC. in 660 EAST ROLLING RIDGE DRIVE, BELLEFONTE, PA 16823 (NAICS 334419). OSHA activity number 341257277.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Piezo Kinetics, INC. — free Get an email when a new federal OSHA severe-injury report for Piezo Kinetics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
660 EAST ROLLING RIDGE DRIVE
City
BELLEFONTE
State
PA
ZIP
16823
Mailing
660 EAST ROLLING RIDGE DRIVE, BELLEFONTE, PA 16823
Inspection type
Monitoring (D)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
55
Ownership type
A

2 citations on file for this inspection.

1910.1025 I01

Serious Gravity 5 1 instance 1 exposed
Issued
May 5, 2016
Penalty
Initial $2,800 · Current $2,100 Reduced

Hazardous substances 1591

29 CFR 1910.1025(i)(1): The employer did not ensure that food or beverage was not present, or consumed; tobacco products were not present, or used and cosmetics were not applied in areas where employees were exposed to lead in excess of the permissible exposure limit:  (a) Powder Production Room - The employer did not ensure that chewing tobacco was not used by an employee in the room near the milling operation, on or about February 17, 2016.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.1025 F03 I C

Other-than-serious 1 instance 5 exposed
Issued
May 5, 2016
Abate by
Jun 9, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(f)(3)(i)(C): The employer did not provide HEPA filters for powered and non-powered air-purifying respirators:  (a) Press Room and Powder Production Room - The employer provided Sperian N95 filtering face-piece respirators instead of air-purifying respirators equipped with HEPA filters (N100), on or about February 17, 2016.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Piezo Kinetics, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341257277.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.