Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VEOLIA NORTH AMERICA, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of VEOLIA NORTH AMERICA, INC. in 7665 TEXAS HWY 73, BEAUMONT, TX 77705 (NAICS 236210). OSHA activity number 341265866.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veolia North America, INC. — free Get an email when a new federal OSHA severe-injury report for Veolia North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7665 TEXAS HWY 73
City
BEAUMONT
State
TX
ZIP
77705
Mailing
7665 TEXAS HWY 73, BEAUMONT, TX 77705
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
180
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 28, 2016
Abate by
Jul 18, 2016
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, protective shields and barriers were not provided:  a) On or about February 11, 2016, at the site, electricians were not provided with personal protective equipment for protection from thermal burns.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.132 D01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 28, 2016
Abate by
Jul 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1):  The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment (PPE):  a) On or about February 11, 2016, at the plant, the hazards of the workplace were not assessed prior to allowing electricians to start the task.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 28, 2016
Abate by
Jul 18, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards created by flying chips and sparks:  a) On or about February 11, 2016, at the job site at the deslagger, electricians were not protected from splashing liquids and steam by a barrier guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

View Veolia North America, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341265866.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.