OSHA Inspection: VEOLIA NORTH AMERICA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VEOLIA NORTH AMERICA, INC. in 500 EAST REYNOLDS ROAD, ARKADELPHIA, AR 71923 (NAICS 562211). OSHA activity number 347205742.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veolia North America, INC. — free Get an email when a new federal OSHA severe-injury report for Veolia North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
500 EAST REYNOLDS ROAD
City
ARKADELPHIA
State
AR
ZIP
71923
Mailing
500 EAST REYNOLDS ROAD, ARKADELPHIA, AR 71923
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562211
Employees
144
Ownership type
A

1 citation on file for this inspection.

1910.1450 E03 III

Other-than-serious Gravity 1 6 instances 7 exposed
Issued
May 13, 2024
Abate by
Jun 7, 2024
Penalty
Initial $6,913 · Current $6,913
29 CFR 1910.1450(e)(3)(iii): The employer's Chemical Hygiene Plan did not include a requirement that fume hoods and other protective equipment functioned properly and did not include specific measures that would be taken to ensure proper and adequate performance of such equipment:    a) On or about January 12, 2024, in the lab, employees analyzing organic vapors such as, but not limited to nitric acid and hydrogen chloride while using an operational fume hood that did not capture all fumes in that Hood 1 did not have a capture velocity of at least 100 feet per minute.  On or about January 12, 2024, in the lab, employees engaged in analyzing organic vapors such as, but not limited to nitric acid and hydrogen chloride used a fume hood that was not incompliance with the hygiene plan in the following instances:  b) Hood 1, the maximum sash opening was not measured and marked clearly and legibly at the working height;  c) Hood 2, the maximum sash opening was not measured and marked clearly and legibly at the working height;  d) Hood 3, the maximum sash opening was not measured and marked clearly and legibly at the working height;  e) Air velocity measurements were taken annually instead of every six months;  f) Records of the velocity readings for each hood were not maintained for comparison.