OSHA Inspection: OWENS CORNING INSULATING SYSTEMS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OWENS CORNING INSULATING SYSTEMS, LLC in 1277 FEURA BUSH RD., FEURA BUSH, NY 12067 (NAICS 327993). OSHA activity number 341270189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Owens Corning Insulating Systems, LLC — free Get an email when a new federal OSHA severe-injury report for Owens Corning Insulating Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1277 FEURA BUSH RD.
City
FEURA BUSH
State
NY
ZIP
12067
Mailing
1277 FEURA BUSH RD., FEURA BUSH, NY 12067
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327993
Employees
305
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 30 exposed
Issued
Jun 1, 2016
Abate by
Jun 22, 2016
Penalty
Initial $7,000 · Current $5,250 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards of (94 feet):    a)   Batch house - On or about February 14, 2016, an employee was trapped in an elevator when the elevator malfunctioned leaving him approximately 94 feet above ground level in subzero temperatures.  The elevator emergency signal could only be heard in the vicinity below the elevator not manned by another employee.  The employee self-rescued by exiting through the top of the elevator and was exposed to a fall hazard of 94'.
Recent events (3)
  • — F (S) $5250
  • — C (S) $7000
  • — Z (S) $7000

1904.4 A

Deleted Other-than-serious 1 instance 1 exposed
Issued
May 16, 2016
Abate by
May 26, 2016
Penalty
Initial $1,000 · Current $0 Reduced
29 CFR 1904.4(a): The employer did not record on the OSHA Form 300 or equivalent each work-related fatality, injury, or illness case that resulted in the general recording criteria:   a) Employer's Office - On or about November 18, 2015, the employer did not record an injury in the injury and illness log where an employee experienced a broken toe at work.  This injury further resulted in days away from work for this employee.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1000

View Owens Corning Insulating Systems, LLC's full OSHA safety record →