SAINT LOUIS, MO ·
OSHA Inspection: WEISSMAN THEATRICAL SUPPLIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WEISSMAN THEATRICAL SUPPLIES in 6750 MANCHESTER AVE., SAINT LOUIS, MO 63139 (NAICS 423410). OSHA activity number 341273308.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEISSMAN THEATRICAL SUPPLIES
- Site address
- 6750 MANCHESTER AVE.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63139
- Mailing
- 6750 MANCHESTER AVE., SAINT LOUIS, MO 63139
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423410
- Employees
- 450
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 II B
- Issued
- May 17, 2016
- Abate by
- Jun 13, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; At the jobsite located 6750 Manchester Avenue, Saint Louis, Missouri, the employer failed to ensure machine specific procedures were developed for maintenance employees(s) who service and maintain five (5) machines with multiple energy sources, including but not limited to: a) Lectra Systèmes - Model Number: Eclipse(VT70FASHION71)/ Serial Number: 3K0526 b) Lectra Systèmes- Model Number: Vector 7000/ Serial Number: 000149 c) Lectra Systèmes-Model Number: Vector 7000(VT70FASHION71)/ Serial Number: 3F523 d) Lectra Systèmes - Model Number: Vector 5000/ Serial Number: 000085 e) Lectra Systèmes - Model Number: Brio System 5
Recent events (1)
- · Z (S) $7000
1910.147 C06 I
- Issued
- May 17, 2016
- Abate by
- Jun 13, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. At the jobsite located 6750 Manchester Avenue, Saint Louis, Missouri, the employer did not conduct periodic inspections of energy control procedures at least annually as required to ensure effectiveness.
Recent events (1)
- · Z (S) $7000
1910.212 A03 IV B
- Issued
- May 17, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(b): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The following are some of the machines which usually require point of operation guarding, shears: At the jobsite located 6750 Manchester Avenue, Saint Louis, Missouri, the employer did not provide adequate guarding to protect an employee who sustained an amputation of left pointer finger while operating a Sheffield Strap Cutting Machine (Model Number: HC-530/ Serial Number: 2143).