TAMPA, FL —
OSHA Inspection: SAMI'S PITA BAKERY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SAMI'S PITA BAKERY, INC. in 2399 EAST BUSCH BLVD., TAMPA, FL 33617 (NAICS 424490). OSHA activity number 341283745.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMI'S PITA BAKERY, INC.
- Site address
- 2399 EAST BUSCH BLVD.
- City
- TAMPA
- State
- FL
- ZIP
- 33617
- Mailing
- 2399 EAST BUSCH BLVD., TAMPA, FL 33617
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424490
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.242 B
- Issued
- Jun 13, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using compressed air to clean material that was at a pressure greater than 30 p.s.i. Air pressure that was used was approximately 110 p.s.i.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.303 B07 I
- Issued
- Jun 13, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused opening in electrical cabinets were not effectively closed provide substantially equivalent protection to the equipment: a) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using an oven that was missing a breaker in the oven panel board.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G02 I
- Issued
- Jun 13, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $700 · Current $350 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using a bread packaging machine that was missing a cover plate exposing energized live parts. b) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using a light switch for the oven that was missing a cover plate exposing energized live parts. c) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using a saw to cut bread that was missing a cover plate exposing energized live parts.
Recent events (2)
- — I (O) $350
- — Z (O) $700
1910.305 B01 I
- Issued
- Jun 13, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using a bread packaging machine and the power cord was not protected from abrasion where it entered the cabinet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Jun 13, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) For employees working at 2399 East Busch Blvd located in Tampa, as observed on or about 10 February, 2016. Employees were using a saw to cut bread and the plug was missing strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sami'S Pita Bakery, INC.