TAMPA, FL —
OSHA Inspection: SAMI'S PITA BAKERY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SAMI'S PITA BAKERY, INC. in 2399 E BUSCH BLVD., TAMPA, FL 33612 (NAICS 311812). OSHA activity number 341870038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMI'S PITA BAKERY, INC.
- Site address
- 2399 E BUSCH BLVD.
- City
- TAMPA
- State
- FL
- ZIP
- 33612
- Mailing
- 2399 E BUSCH BLVD., TAMPA, FL 33612
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 12, 2017
- Abate by
- Apr 24, 2017
- Penalty
- Initial $4,182 · Current $1,046 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Near the entry area of the pita oven and above the wooden shelf, an intake section of blower was missing a guard, as observed on or about 10/27/2016.
Recent events (2)
- — I (S) $1045.5
- — Z (S) $4182
1910.303 B02
- Issued
- Apr 12, 2017
- Abate by
- May 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Metal box with attached electrical conduit was observed lying on top of a bread proofer, on or about 10/27/2016. (b) Plastic boxes with electrical conduit were observed being held up by securing a piece of wire to them and connecting them to the outside of the pita bread oven to stop it from falling forward, on or about 10/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Apr 12, 2017
- Abate by
- Apr 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Outside the pita oven entry, electrical components where constructed above a wooden platform where an unused opening was observed, on or about 10/27/2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Apr 12, 2017
- Abate by
- Apr 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) For the mixer and scale, two extension cords were dropped from the ceiling to provide power, as observed on or about 10/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Apr 12, 2017
- Abate by
- Apr 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: (a) In the prep area, for a floor mixer whose electrical power source was coming from an extension cord dropped through the ceiling, as observed on or about 10/27/2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Apr 12, 2017
- Abate by
- Apr 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) For the taped conduit end going from the motor to the control of the pita bread motor conveyor, as observed on or about 10/27/16. (b) For the taped conduit end going into a solenoid valve located above the wooden shelf of the entry conveyor for the pita bread oven, as observed on 10/27/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sami'S Pita Bakery, INC.
View Sami'S Pita Bakery, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341870038.