Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAMI'S PITA BAKERY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SAMI'S PITA BAKERY, INC. in 2399 E BUSCH BLVD., TAMPA, FL 33612 (NAICS 311812). OSHA activity number 341870038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sami'S Pita Bakery, INC. — free Get an email when a new federal OSHA severe-injury report for Sami'S Pita Bakery, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2399 E BUSCH BLVD.
City
TAMPA
State
FL
ZIP
33612
Mailing
2399 E BUSCH BLVD., TAMPA, FL 33612
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
40
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $4,182 · Current $1,046 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)  Near the entry area of the pita oven and above the wooden shelf, an intake section of blower was missing a guard, as observed on or about 10/27/2016.
Recent events (2)
  • — I (S) $1045.5
  • — Z (S) $4182

1910.303 B02

Other-than-serious 2 instances 40 exposed
Issued
Apr 12, 2017
Abate by
May 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  Metal box with attached electrical conduit was observed lying on top of a bread proofer, on or about 10/27/2016.  (b) Plastic boxes with electrical conduit were observed being held up by securing a piece of wire to them and connecting them to the outside of the pita bread oven to stop it from falling forward, on or about 10/27/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Outside the pita oven entry, electrical components where constructed above a wooden platform where an unused opening was observed, on or about 10/27/2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 2 instances 40 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) For the mixer and scale, two extension cords were dropped from the ceiling to provide power, as observed on or about 10/27/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV B

Other-than-serious 1 instance 40 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  (a) In the prep area, for a floor mixer whose electrical power source was coming from an extension cord dropped through the ceiling, as observed on or about 10/27/2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 2 instances 1 exposed
Issued
Apr 12, 2017
Abate by
Apr 24, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) For the taped conduit end going from the motor to the control of the pita bread motor conveyor, as observed on or about 10/27/16.  (b) For the taped conduit end going into a solenoid valve located above the wooden shelf of the entry conveyor for the pita bread oven, as observed on 10/27/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Sami'S Pita Bakery, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341870038.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.