MOUNT VERNON, NY —
OSHA Inspection: MUNN WORKS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MUNN WORKS, LLC in 150 NORTH MACQUESTEN PARKWAY, MOUNT VERNON, NY 10550 (NAICS 327215). OSHA activity number 341285062.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MUNN WORKS, LLC
- Site address
- 150 NORTH MACQUESTEN PARKWAY
- City
- MOUNT VERNON
- State
- NY
- ZIP
- 10550
- Mailing
- 150 NORTH MACQUESTEN PARKWAY, MOUNT VERNON, NY 10550
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327215
- Employees
- 25
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 C06
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $1,600 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: Location: Spray Room a) The exhaust fan located in the spray room was not explosion-proof type approved for Class 1, group D locations; on or about 2/24/17.
Recent events (2)
- — I (S) $1250
- — Z (S) $1600
1910.107 C07
- Issued
- Apr 8, 2016
- Abate by
- May 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not protected from mechanical injury by suitable guards or by location Location: Spray room a) Fluorescent lights were within 11ft of the spray area and were were not covered; on or about 2/24/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. Location: Production area a) The employer requires employees to wear half-face negative pressure respirators when spray painting and cutting wood. The employer did not establish or implement a written respiratory protection program; on or about 2/24/16.
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
1910.134 E01
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. Location: Production area a) The employer requires employees to wear half-face negative pressure respirators when spray painting and cutting wood. The employer did not provide a medical evaluation for employees before they were required to use respirators in the workplace; on or about 2/24/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) Location: Production area a) The employer requires employees to wear half-face negative pressure respirators when spray painting and cutting wood. The employer did not require employees to pass an appropriate (QLFT) or quantitative fit test (QNFT) before they were required to use a respirator in the workplace; on or about 2/24/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $1,600 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: Location: Workplace a) Employees work with hazardous chemicals such as but not limited to Methylene bis(phenylisocyanate), Diisononyl phthalate and wood dust and the employer did not develop or implement a written hazard communication program; on or about 2/4/16.
Recent events (2)
- — I (S) $1250
- — Z (S) $1600
1910.1200 G08
- Issued
- Apr 8, 2016
- Abate by
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s) Location: Workplace a) Employees work with hazardous chemicals such as paints and primers and the employer did not maintain the safety data sheets for each hazardous chemical in the workplace; on or about 2/4/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Apr 8, 2016
- Abate by
- May 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. Location: Workplace a) Employees work with hazardous chemicals such as but not limited to Methylene bis(phenylisocyanate), Diisononyl phthalate and wood dust and the employer did not provide hazard communication training; on or about 2/4/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Munn Works, LLC
View Munn Works, LLC's full OSHA safety record →
More inspections in this industry (NAICS 327215)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341285062.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.