Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MUNN WORKS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MUNN WORKS, LLC in 150 NORTH MACQUESTEN PARKWAY, MOUNT VERNON, NY 10550 (NAICS 327215). OSHA activity number 341293058.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Munn Works, LLC — free Get an email when a new federal OSHA severe-injury report for Munn Works, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MUNN WORKS, LLC
Site address
150 NORTH MACQUESTEN PARKWAY
City
MOUNT VERNON
State
NY
ZIP
10550
Mailing
150 NORTH MACQUESTEN PARKWAY, MOUNT VERNON, NY 10550
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327215
Employees
35
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 2 instances 8 exposed
Issued
May 20, 2016
Penalty
Initial $2,800 · Current $2,250 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition:    a) Wood shop- The passageways and work areas employees are required to access, were not kept clean and orderly and were blocked by boxes, frames and other wood materials; on or about 2/24/16.    b) Inside the Annex- The passageways and work areas employees are required to access, were not kept clean and orderly and were blocked by boxes, frames and other wood materials; on or about 2/24/16.
Recent events (3)
  • — J (S) $2250
  • — C (S) $2800
  • — Z (S) $2800

1910.37 A03

Serious Gravity 5 2 instances 8 exposed
Issued
May 20, 2016
Penalty
Initial $3,500 · Current $2,813 Reduced
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed:     a) Production Area- Exit route, in the event of an emergency, was blocked by wooden frames and wooden shipment boxes; on or about 02/24/16.    b) Annex- Exit door, in the event of an emergency, was blocked by a wooden table top; on or about 02/24/16.
Recent events (3)
  • — J (S) $2813
  • — C (S) $3500
  • — Z (S) $3500

1910.157 C01

Serious Gravity 5 1 instance 3 exposed
Issued
May 20, 2016
Abate by
Jun 9, 2016
Penalty
Initial $2,800 · Current $2,250 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:      a) Annex- The fire extinguisher was blocked and not readily accessible to employees during an emergency; on or about 02/24/16.
Recent events (3)
  • — J (S) $2250
  • — C (S) $2800
  • — Z (S) $2800

1910.213 H01

Serious Gravity 10 1 instance 1 exposed
Issued
May 20, 2016
Abate by
Jun 9, 2016
Penalty
Initial $4,900 · Current $3,937 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the materials being cut:    a) Annex- The bottom section of the Ridgid miter saw cutting blade was not guarded; on or about 2/24/16.
Recent events (3)
  • — J (S) $3937
  • — C (S) $4900
  • — Z (S) $4900

1910.303 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 20, 2016
Abate by
Jun 9, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.  a) Sanding room- Employees were using a surge protector that was intended for home/office use only; on or about 02/24/16.
Recent events (3)
  • — J (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.303 G01 II

Serious Gravity 5 1 instance 5 exposed
Issued
May 20, 2016
Abate by
Jun 9, 2016
Penalty
Initial $2,800 · Current $2,250 Reduced
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage:    a) Wood shop area- The space in front of a 240 volt electrical panel was used for storage; on or about 2/24/16.
Recent events (3)
  • — J (S) $2250
  • — C (S) $2800
  • — Z (S) $2800

View Munn Works, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341293058.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.