ONTARIO, NY —
OSHA Inspection: OPTIPRO SYSTEMS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of OPTIPRO SYSTEMS, LLC in 6368 DEAN PARKWAY, ONTARIO, NY 14519 (NAICS 333249). OSHA activity number 341287522.
Where did this inspection happen?
- Establishment
- OPTIPRO SYSTEMS, LLC
- Site address
- 6368 DEAN PARKWAY
- City
- ONTARIO
- State
- NY
- ZIP
- 14519
- Mailing
- 6368 DEAN PARKWAY, ONTARIO, NY 14519
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 73
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Manual Machining Area, on or about 2/29/19: Hardinge Lathe, the rotating chuck was not guarded. b) Manual Machining Area, on or about 2/29/19: Clausing Drill Press was not provided with a chuck and tool guard. c) Manual Machining Area, on or about 2/29/19: Bridgeport Mill was not provided with a chuck and tool guard. d) Manual Machining Area, on or about 2/29/19: Hyd-Mech Band Saw was not protected with a guard on the unused portion of the blade on the left side.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.303 G02 I
- Issued
- Penalty
- Initial $3500.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) Electrical Room, on or about 2/29/16: 480 volt breaker panel box had the front panel not screwed down allowing exposed energized parts to be accessible.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.304 F01 IV
- Issued
- Penalty
- Initial $1785.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less were not readily accessible to each employee or authorized building management personnel: a) APD Lab, on or about 2/29/16: Access to a 120/240 volt breaker panel box was blocked by a cut off saw.
Recent events (2)
- — I (S) $0
- — Z (S) $1785
1904.32 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.32(a)(4): The annual summary of occupational injuries and illnesses (applicable portion of OSHA Form No. 300) was not posted: a) Optipro Systems, LLC., on or about 2/29/16: The OSHA 300A for calendar year 2015 was not posted by February 1, 2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) Optipro Systems, LLC., on or about 2/29/16: Employer had not completed a fork lift training certificate for employees who had been trained and evaluated in fork lift operator training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at OPTIPRO SYSTEMS, LLC
ONTARIO, NY—2009-11-25 00:00:00
OPTIPRO SYSTEMS LLC
ONTARIO, NY—2009-11-20 00:00:00
OPTIPRO SYSTEMS LLC
View OPTIPRO SYSTEMS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333249)
NORTON SHORES, MI—2026-06-30
I D SYSTEMS INC DBA INTER DYNE SYSTEMS
SAINT LOUIS, MO—2026-06-23
WEIR MINERALS LEWIS PUMPS
AUBURN HILLS, MI—2026-06-10
ANDROID INDUSTRIES LLC
EGG HARBOR TOWNSHIP, NJ—2026-06-09
JOMAR CORPORATION
BUTTE, MT—2026-05-27
RESODYN CORPORATION
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source