Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: OPTIPRO SYSTEMS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of OPTIPRO SYSTEMS, LLC in 6368 DEAN PARKWAY, ONTARIO, NY 14519 (NAICS 333249). OSHA activity number 341287522.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Optipro Systems, LLC for free Get an email when a new federal OSHA severe-injury report for Optipro Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6368 DEAN PARKWAY
City
ONTARIO
State
NY
ZIP
14519
Mailing
6368 DEAN PARKWAY, ONTARIO, NY 14519
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
73
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 3 exposed
Issued
Mar 8, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:     a)  Manual Machining Area, on or about 2/29/19: Hardinge Lathe, the rotating chuck was not guarded.    b) Manual Machining Area, on or about 2/29/19: Clausing Drill Press was not provided with a chuck and tool guard.    c)  Manual Machining Area, on or about 2/29/19: Bridgeport Mill was not provided with a chuck and tool guard.    d)  Manual Machining Area, on or about 2/29/19: Hyd-Mech Band Saw was not protected with a guard on the unused portion of the blade on the left side.
Recent events (2)
  • · I (S) $1960
  • · Z (S) $2800

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 8, 2016
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    a)  Electrical Room, on or about 2/29/16: 480 volt breaker panel box had the front panel not screwed down allowing exposed energized parts to be accessible.
Recent events (2)
  • · I (S) $2450
  • · Z (S) $3500

1910.304 F01 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 8, 2016
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less were not readily accessible to each employee or authorized building management personnel:      a)  APD Lab, on or about 2/29/16: Access to a 120/240 volt breaker panel box was blocked by a cut off saw.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1785

1904.32 A04

Other-than-serious 1 instance 25 exposed
Issued
Mar 8, 2016
Abate by
Mar 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(4): The annual summary of occupational injuries and illnesses (applicable portion of OSHA Form No. 300) was not posted:   a) Optipro Systems, LLC., on or about 2/29/16: The OSHA 300A for calendar year 2015 was not posted by February 1, 2016.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Mar 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a)  Optipro Systems, LLC., on or about 2/29/16: Employer had not completed a fork lift training certificate for employees who had been trained and evaluated in fork lift operator training.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Optipro Systems, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341287522.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.