Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: CROWN EQUIPMENT CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CROWN EQUIPMENT CORPORATION in 104 BAUER DRIVE, OAKLAND, NJ 07436 (NAICS 333924). OSHA activity number 341304632.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crown Equipment Corporation for free Get an email when a new federal OSHA severe-injury report for Crown Equipment Corporation is published. One employer, no account, unsubscribe in one click.
Site address
104 BAUER DRIVE
City
OAKLAND
State
NJ
ZIP
07436
Mailing
104 BAUER DRIVE, OAKLAND, NJ 07436
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333924
Employees
62
Ownership type
Private (A)

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Apr 14, 2016
Penalty
Initial $5,000 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard.   Shop Area: Employees were using a Yale electric chain hoist, rated at 3 tons, without a safety latch installed on the hook, to lift equipment, including but not limited to, small and large size batteries and other forklift parts. The employer failed to install a safety latch on the Wilbart hook as per ANSI B30.16-2012, Section 16-1.2.9 (hooks), thereby exposing employees to a struck by hazard, on or about, 3/7/16.
Recent events (3)
  • · F (S) $0
  • · C (S) $5000
  • · Z (S) $5000

1910.101 B

Other-than-serious 1 instance 2 exposed
Issued
Apr 14, 2016
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-2015, which is incorporated by reference as specified in CFR 1910.101:    a) Compressed Gas Storage (Outdoors): Acetylene, propane and oxygen compressed gas cylinders were stored together. The employer failed to separate compressed fuel gas cylinders from oxygen gas cylinders, as per Section 6.2.1 of the Compressed Gas Association Pamphlet P-1-2015, on or about, 3/7/16.
Recent events (3)
  • · F (O) $2000
  • · C (S) $4000
  • · Z (S) $4000

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Apr 14, 2016
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  a) Spray Finishing: An employee is required to wear a 3M dual half mask dual cartridge respirator during spray finishing operations and the employee had not completed fit testing. The employer failed to ensure that affected employees were provided fit testing on an annual basis, on or about, 3/7/16.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

View Crown Equipment Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341304632.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.