1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: AUBURN VACUUM FORMING CO. INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AUBURN VACUUM FORMING CO. INC. in 40 YORK STREET, AUBURN, NY 13021 (NAICS 326199). OSHA activity number 341304871.

Watch Auburn Vacuum Forming CO. INC. — free Get an email when a new federal OSHA severe-injury report for Auburn Vacuum Forming CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
40 YORK STREET
City
AUBURN
State
NY
ZIP
13021
Mailing
PO BOX 489, AUBURN, NY 13021
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
12
Ownership type
A

1 citation on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1680.00 Reduced
29 CFR 1910.95(c)(1):  A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average (TWA) sound level of 85 dBA:    At the vacuum forming area, on or about 3/31/2016:  An employee operating the Howard Leigh MultiMax was exposed to continuous noise at a sound level of approximately 91.8 dBA (8 hour time weighted average) during the 435 minute sampling period on 3/31/2016.  Exposure calculations include a zero increment for the 45 minutes not sampled.      Abatement documentation must be submitted for this citation.    An effective hearing conservation program in accordance with 29 CFR 1910.95(c) through (n) shall include, at a minimum:         (1) Initial monitoring to determine if employee exposure to noise exceeds the 85 dBA 8 hour TWA action level.        (2) A baseline audiogram for all employees exposed to noise levels equal to or in excess of the 85 dBA 8 hour TWA.        (3) Annual audiograms for each overexposed employee.        (4) Analysis of audiogram results with retesting an/or referral to an otolaryngologist or qualified physician when a significant threshold shift occurs.  A significant shift will be considered to be equal to or greater than an average of 10 dBA over the 2000, 3000, and 4000 hertz frequencies.         (5) Where insert ear plugs or custom-molded devices are utilized, individual employee fitting shall be conducted by a trained person, and employees shall be instructed in the care and use of the devices.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

View AUBURN VACUUM FORMING CO. INC.'s full OSHA safety record →