AUBURN, NY ·
OSHA Inspection: AUBURN VACUUM FORMING CO. INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AUBURN VACUUM FORMING CO. INC. in 40 YORK STREET, AUBURN, NY 13021 (NAICS 326199). OSHA activity number 341304871.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUBURN VACUUM FORMING CO. INC.
- Site address
- 40 YORK STREET
- City
- AUBURN
- State
- NY
- ZIP
- 13021
- Mailing
- PO BOX 489, AUBURN, NY 13021
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 12
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.95 C01
- Issued
- Apr 6, 2016
- Abate by
- May 11, 2016
- Penalty
- Initial $2,400 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average (TWA) sound level of 85 dBA: At the vacuum forming area, on or about 3/31/2016: An employee operating the Howard Leigh MultiMax was exposed to continuous noise at a sound level of approximately 91.8 dBA (8 hour time weighted average) during the 435 minute sampling period on 3/31/2016. Exposure calculations include a zero increment for the 45 minutes not sampled. Abatement documentation must be submitted for this citation. An effective hearing conservation program in accordance with 29 CFR 1910.95(c) through (n) shall include, at a minimum: (1) Initial monitoring to determine if employee exposure to noise exceeds the 85 dBA 8 hour TWA action level. (2) A baseline audiogram for all employees exposed to noise levels equal to or in excess of the 85 dBA 8 hour TWA. (3) Annual audiograms for each overexposed employee. (4) Analysis of audiogram results with retesting an/or referral to an otolaryngologist or qualified physician when a significant threshold shift occurs. A significant shift will be considered to be equal to or greater than an average of 10 dBA over the 2000, 3000, and 4000 hertz frequencies. (5) Where insert ear plugs or custom-molded devices are utilized, individual employee fitting shall be conducted by a trained person, and employees shall be instructed in the care and use of the devices.
Recent events (2)
- · I (S) $1680
- · Z (S) $2400
More inspections at Auburn Vacuum Forming CO. INC.
View Auburn Vacuum Forming CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341304871.